Final | 9/6/2018 | 9/10/2018 | 9/10/2018 | A | PASS |
Mark Moncarr
|
|
|
Phone #: ###-#### Inspection requested via web by Jonathan Poot Ok final. Auto cover and lights function properly.
|
Final | 9/5/2018 | 9/6/2018 | 9/6/2018 | A | CANC |
Mark Moncarr
|
|
|
Pool cover wiring and bonding is complete. Phone #: ###-#### Inspection requested via web by Jonathan Poot No access. Talked to contractor. He is going to schedule a time for access.
|
Final | 8/31/2018 | 9/4/2018 | 9/4/2018 | A | FAIL |
Mark Moncarr
|
|
|
Need verification of bondimg ispection for pool. Pool is existing. Bonding needed for metal pool cover for cover. Junction box needed for splice powering motor. Talked to contractor, he is going to get fixed and call back in when complete. Home is occupied, and looks like pool has been used. Pool not to be used until items are corrected.
|
Final | 8/31/2018 | 8/31/2018 | 8/31/2018 | P | CANC |
Eric Story
|
|
|
We just need the pool cover inspected. It was not wired permantly during the previous final inspection. Thank you. Phone #: ###-#### Inspection requested via web by Jonathan Poot Rescheduled for Mark on tuesday, I didnt see any records of bonding for perimeter of pool and for metal parts within 5' of pool edge
|
Final | 8/22/2018 | 8/23/2018 | 8/23/2018 | A | NR |
Mark Moncarr
|
|
|
Phone #: ###-#### Inspection requested via web by Jonathan Poot House is good. Pool not ready for final. Extension cord used to temp power for auto cover.
|
Electrical Rough-In | 7/9/2018 | 7/9/2018 | 7/9/2018 | P | PASS |
Mark Moncarr
|
|
|
We just need an underground conduit inspected to a detached building. From the main service behind the house to old garage. Phone #: ###-#### Inspection requested via web by Jonathan Poot Ok cover trench garage to house.
|
Rough-In Permanent Service | 4/30/2018 | 4/30/2018 | 4/30/2018 | P | PASS |
Mark Moncarr
|
|
|
Phone #: ###-#### Inspection requested via web by Jonathan Poot p/s o/h n ok. Recess cans above pool but out of 12' zone.
|
Rough-In Permanent Service | 4/27/2018 | 4/30/2018 | 4/30/2018 | A | FAIL |
James Ady
|
|
|
Phone #: ###-#### Inspection requested via web by Jonathan Poot 210.11C4 Garage recep circuit shall have no other. (251.120 Equipment grounding Conductor and 250.142 Use of grounded conductor as equipment ground. Sub panel needs equipment ground) 210.52E Each porch, balcony and deck shall have recep( Fornt Porch) Finish securing and stubbing exterior lighting.
|
Issue PAID IN FULL permit | | | 4/17/2018 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 4/17/2018 | | DONE |
|
|
|
This permit was created on the web by Jonathan Poot
|