Final | 8/3/2018 | 8/3/2018 | 8/3/2018 | P | PASS |
Tom Saunders
|
|
|
Ron-added AFI breaker Phone #: ###-####.. corrections made...ok to final
|
Final | 7/31/2018 | 7/31/2018 | 7/31/2018 | P | FAIL |
Tom Saunders
|
|
|
code 5151 Phone #: ###-#### Inspection requested via web by ron spen cer... 1..can trim in master shower shall be rated for damp/wet location..410.10(D) 2..all 120V 15/20A circuits supplying outlets or devices installed in bedroom shall have AFCI protection..210.12(A)...patio light switch in mst bedroom
|
Conference | 6/13/2018 | 6/13/2018 | 6/13/2018 | P | CANC |
Tom Saunders
|
|
|
Ron--heated floor inspection-left reading for cable in box Phone #: 208-409- ...needed rough inspection...scheduled and resulted
|
Electrical Rough-In | 6/13/2018 | 6/13/2018 | 6/13/2018 | P | PASS |
Tom Saunders
|
|
|
Ron--heated floor inspection-left reading for cable in box Phone #: ###-####...ok to cover mst bath heated floor
|
Rough-In Permanent Service | 4/23/2018 | 4/23/2018 | 4/23/2018 | P | PASS |
Tom Saunders
|
|
|
Phone #: ###-#### Inspection requested via web by ron spen cer...rough ok to cover...p/s u/g new ok
|
Rough-In Permanent Service | 4/23/2018 | 4/23/2018 | 4/23/2018 | P | CANC |
Tom Saunders
|
|
|
Phone #: ###-#### Inspection requested via web by ron spen cer...scheduled twice
|
Issue PAID IN FULL permit | | | 4/23/2018 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 4/23/2018 | | DONE |
|
|
|
This permit was created on the web by ron spen cer
|