Permit NumberELE18-01607
StatusFinaled
Name MITCHELL ENTERPRISES INC
Site Address 11473 W JENILYN CT
Project Name 
Customer Number44674
ePlanReviewNo
Description
Alteration or Repair: Install new 240v 20a circuit from the existing sub panel by the pumps to the shed for the air compressor. Extend the existing GFCI protected circuit from the recruiter if the shed into the shed for a new receptacle and light.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final6/5/20186/6/20186/6/2018APASS
DetailsTom Saunders
If you have any questions please call Jeremiah at ###-####. Thank you! Phone #: ###-#### Inspection requested via web by Dan Mitchell...corrections made...ok to final
Final4/27/20184/30/20184/30/2018AFAIL
DetailsTom Saunders
Please call March at ###-#### for access. If you have any questions please call Jeremiah at ###-####. Thank you! Phone #: ###-#### Inspection requested via web by Dan Mitchell..
1..romex shall not be exposed to physical damage..334.15

2..romex shall not be used in wet or damp locations...334.12(B)

3..outlets shall be of weather resistant type..406.9

4..S/O cord shall be rated heavy duty use to wire air compressor or protected from physical damage...needs replaced-is all ready weathered and cracked and cannot be used to wire compressor

5..access to panel is required...unable to verify breaker...panels shall have 3' clearance..readily accessible meaning no tool...110.26
Issue PAID IN FULL permit  4/27/2018 DONE
Payment received via Govolutions
Application received  4/27/2018 DONE
This permit was created on the web by Dan Mitchell