Final | 9/26/2018 | 9/27/2018 | 9/27/2018 | A | PASS |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Kevin Perez Final ok
|
Final | 9/24/2018 | 9/25/2018 | 9/25/2018 | P | FAIL |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Kevin Perez 110.3- Devices not working, dead reeptacles in dining room, family room, up master bedroom, open neutral in family room. 300.22(B)- Electrical wiring and devices shall not be located in a duct. NM cable and non-metellic box located in area used as return air space under stairs. 406.6- Missing receptacle cover in master bedroom behind closet door. 410.16- Recessed can trims in master closet shall have totally enclosed lamps.
|
Electrical Rough-In | 8/2/2018 | 8/3/2018 | 8/3/2018 | A | PASS |
Rock A. Hudson
|
|
|
Please call prior to arrival for access. ###-#### Phone #: ###-#### Inspection requested via web by Kevin Perez Kitchen and up master bathroom. Rough in ok cover.
|
Electrical Rough-In | 8/1/2018 | 8/2/2018 | 8/2/2018 | P | NR |
Rock A. Hudson
|
|
|
Please call prior for access. Call Jarod at Mountain Power ###-#### for access key code. Phone #: ###-#### Inspection requested via web by Kevin Perez Misc wiring to complete and misc make up Recall when complete.
|
Electrical Rough-In | 6/1/2018 | 6/4/2018 | 6/4/2018 | A | PART |
Rock A. Hudson
|
|
|
Rough-in for master bed area Phone #: ###-#### Inspection requested via web by Kevin Perez Homeowner had 1st general contactor skip town now has another to complete work. Some patch work in upstair ceiling only ok
|
Issue PAID IN FULL permit | | | 6/1/2018 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 6/1/2018 | | DONE |
|
|
|
This permit was created on the web by Kevin Perez
|