ELE-Aging Inspection | 6/29/2020 | 6/29/2020 | 6/29/2020 | | PEND |
Daryl DeGrange
|
|
|
The permit is still open with the City of Boise. Please call 208 ###-#### with progress report or any questions. If your job is complete, please schedule an final inspection online. Thank you!
|
Final | 6/21/2018 | 6/22/2018 | 6/22/2018 | P | CANC |
Tom Saunders
|
|
|
Ian Phone #: ###-####...not ready at this time...changed to rough in inspection
|
Electrical Rough-In | 6/22/2018 | 6/22/2018 | 6/22/2018 | P | PASS |
Tom Saunders
|
|
|
Ian Phone #: ###-####...EQ potential bonding and rough of shed for pool equipment...discussed 3' needed clearance infront of pool sub panel...will move...also wire from house to pool shed needs to be #6 THHN...romex not aloud for use outside or underground
|
Electrical Rough-In | 6/13/2018 | 6/13/2018 | 6/13/2018 | P | PASS |
Tom Saunders
|
|
|
Ian-underground Phone #: ###-####...ok to cover from house to shed power for pool...discussed that pipe exposed above ground must be sch80 not 40...will fix
|
Conference | 6/5/2018 | 6/6/2018 | 6/6/2018 | A | PASS |
Tom Saunders
|
|
|
call when you are on your way- 8:30-11 please Ian Phone #: ###-####...discussed requirements for fiberglass pool...bonding, GFCI protection, eqpotential grid, inspections...homeowner competent
|
Application received | | | 6/5/2018 | | |
|
|
|
|
Issue PAID IN FULL permit | | | 6/5/2018 | | DONE |
|
|
|
|