Final | 8/21/2018 | 8/21/2018 | 8/21/2018 | A | PASS |
Rock A. Hudson
|
|
|
Garage code 1957E Phone #: ###-#### Inspection requested via web by Alan Lusk Final ok
|
Final | 8/16/2018 | 8/17/2018 | 8/17/2018 | A | NR |
James Ady
|
|
|
garage code 1957e Phone #: ###-#### Inspection requested via web by Alan Lusk Not ready
|
Final | 8/15/2018 | 8/15/2018 | 8/15/2018 | P | FAIL |
Rock A. Hudson
|
|
|
Garage code 1957e Phone #: ###-#### Inspection requested via web by Alan Lusk 110.3- Areas not complete- garage receptacles not working, 1/2 of kitchen and pantry receptacles not working, disposal cord, hood hook up. 210.52(B)- Kitchen counter top receptacles, no point measured along wall line shall be more than 24" from a receptacle outlet. kitchen window wall 5'5" between receptacles. 314.25- All boxes shall have covers. Bathroom vanity lights level 1&2, Device cover level 1 brick wall and level 3 switch covers.
|
Rough-In Permanent Service | 6/11/2018 | 6/13/2018 | 6/13/2018 | A | PASS |
James Ady
|
|
|
Phone #: ###-#### Inspection requested via web by Alan Lusk rough in ok p/s u/g n ok
|
Issue PAID IN FULL permit | | | 6/11/2018 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 6/11/2018 | | DONE |
|
|
|
This permit was created on the web by Alan Lusk
|