Final | 8/29/2018 | 8/30/2018 | 8/30/2018 | A | PASS |
James Ady
|
|
|
Phone #: ###-#### Inspection requested via web by Quentin Hoffpaui Corections made final ok
|
Final | 8/27/2018 | 8/29/2018 | 8/29/2018 | P | FAIL |
James Ady
|
|
|
Phone #: ###-#### Inspection requested via web by Quentin Hoffpauir 210.8 Kitchen counter receps shall be GFCI protected.(Rt and Lt of cooktop.) 210.52C5Exception. Recep shall not be located more than 6in from counter edge
|
Final | 8/27/2018 | 8/27/2018 | 8/27/2018 | P | NR |
James Ady
|
|
|
Phone #: ###-#### Inspection requested via web by Quentin Hoffpauir
|
Electrical Rough-In | 7/10/2018 | 7/11/2018 | 7/11/2018 | P | PASS |
James Ady
|
|
|
Garage code 1002. Please call me before heading over. Thanks, Quentin Phone #: ###-#### Inspection requested via web by Quentin Hoffpauir Corrections made Kitchen only rough in ok
|
Electrical Rough-In | 7/9/2018 | 7/10/2018 | 7/10/2018 | P | FAIL |
James Ady
|
|
|
please call 30 minutes before heading out that way. Thanks Phone #: ###-#### Inspection requested via web by Quentin Hoffpauir 210.11C1 Small appliance circuits shall have no other outlets(Kitchen undercounter lights)
|
Issue PAID IN FULL permit | | | 7/5/2018 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 7/5/2018 | | DONE |
|
|
|
This permit was created on the web by Quentin Hoffpauir
|