Final | 10/26/2018 | 10/26/2018 | 10/26/2018 | P | PASS |
Mark Moncarr
|
|
|
PLEASE CALL CORBIN ahead of time so he can meet you there. ###-#### We had this scheduled for 10/26am but no one was at the house Phone #: ###-#### Inspection requested via web by Samatha Solberg Ok final. Corrections made.
|
Final | 10/25/2018 | 10/26/2018 | 10/26/2018 | A | NH |
Rock A. Hudson
|
|
|
Corbin ###-#### Phone #: ###-#### Inspection requested via web by Samatha Solberg No answer at door. Owner stated living in basement on previous inspection. Due to residence occupied someone must be home fro entry.
|
Final | 10/22/2018 | 10/22/2018 | 10/22/2018 | P | FAIL |
Rock A. Hudson
|
|
|
Corbin ###-#### Phone #: ###-#### Inspection requested via web by Samatha Solberg 210.8- Receptacle serving hutch counter top shall have GFCI protection. 210.52(B)(2)- Kitchen appliance circuits shall have no other outlets. Over sink and under cabinet lighting on with kitchen appliance. 210.52(C)- Receptacle outlets shall be located with in 24" of each side of kitchen sink. 314.20- Boxes mounted in a combustible wall material shall have an extension ring installed flush with surface. Appliance garage, hutch, disposal.
|
Electrical Rough-In | 7/6/2018 | 7/9/2018 | 7/9/2018 | P | PASS |
James Ady
|
|
|
Justin ###-#### Phone #: ###-#### Inspection requested via web by Samatha Solberg Kitchen only ok to cover
|
Issue PAID IN FULL permit | | | 7/6/2018 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 7/6/2018 | | DONE |
|
|
|
This permit was created on the web by Samatha Solberg
|