Final | 9/17/2019 | 9/17/2019 | 9/17/2019 | P | PASS |
Rock A. Hudson
|
|
|
Final ok
|
Final | 9/16/2019 | 9/17/2019 | 9/17/2019 | A | FAIL |
Eric Story
|
|
|
Lock Box 5700. Call Andrew with any questions please ###-####. Thanks!! Phone #: ###-#### Inspection requested via web by Clayton Morgan Basement recepts in-op
|
Rough-In Permanent Service | 8/7/2018 | 8/13/2018 | 8/14/2018 | P | PASS |
James Ady
|
|
|
Fred Phone #: ###-#### house ok to cover garage will be surface mount. check for 2 receps and mondoor light at final ok to cover p/s o/h rec ok
|
Override - Parcel Holds | 8/7/2018 | 1/1/1900 | 8/7/2018 | | |
|
|
|
stop work order not for ele permit
|
Telephone call | | | 8/7/2018 | | DONE |
|
|
|
per phone call from Sunblime Electric, added 1 ps under 200.
|
Conference | 7/23/2018 | 7/23/2018 | 7/23/2018 | P | DONE |
Rock A. Hudson
|
|
|
Luke Phone #: ###-#### Discussed required items that shall be installed to code. Verify minimum 20 amp appliance circuits are present. Kitchen receptacle layout complies. Bathroom receptacles shall have a dedicated 20 amp circuit. Required wall receptacles for kitchen area, living, dining. Add smoke detectors for main floor and basement. Grounding type receptacles installed on ungrounded circuits shall have GFCI protection or change to 2 wire receptacles. No AFCI required no work done in beds. 6-3 in basement shall be removed, owner eventually wants range in basement. Not zoned or designed for range in basement. AC unit is new and shall provide a minimum of 3' from gas meter. A receptacle outlet shall be located with in 25' of AC unit. All wiring in garage that has been installed by prior owner or tenant shall be remove due to none is installed to NEC. Receptacle exists in front of house shall have GFCI protection.
|
Override - Parcel Holds | 7/23/2018 | 1/1/1900 | 7/23/2018 | | |
|
|
|
Fees pain in full
|
Issue PAID IN FULL permit | | | 7/18/2018 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 7/18/2018 | | DONE |
|
|
|
This permit was created on the web by Clayton Morgan
|