Final | 5/1/2019 | 5/2/2019 | 5/2/2019 | A | PASS |
Mark Moncarr
|
|
|
Lawrence Phone #: ###-#### Ok final. 2 GFI brkrs installed and 1 panel blank.
|
Final | 4/22/2019 | 4/23/2019 | 4/23/2019 | A | NR |
Mark Moncarr
|
|
|
call for access- Lawrence Phone #: ###-####
|
Electrical Rough-In | 8/31/2018 | 9/4/2018 | 9/4/2018 | A | PASS |
Mark Moncarr
|
|
|
Lawrence Phone #: ###-#### Ok cover pool border for concrete. Bonding boots present for hand rail and diving board. Light on N end bonded. 4 corners bonded.
|
Electrical Rough-In | 8/22/2018 | 8/23/2018 | 8/23/2018 | P | PASS |
Mark Moncarr
|
|
|
Lawrence Phone #: ###-#### Measurement of overhead line is over the 10' requirement. Permit holder had a string line set up to show that waters edge is not within 10' horizontal. Ok cover light at N end of pool.
|
Conference | 8/20/2018 | 8/21/2018 | 8/21/2018 | A | DONE |
Mark Moncarr
|
|
|
Lawrence Phone #: ###-#### Discussed bonding of in ground metal pool with fiberglass stairs on one end. Ladder for pool has bonding boots. Overhead service drop withing the 10' horizontal distance by a few inches. Homeowner is going to talk to IDP to see if overhead can be moved to the N of pools edge.
|
Application received | | | 8/20/2018 | | DONE |
|
|
|
This permit was created on the web by Lawrence Fields-homeowner came in and finished pulling permit in office-see app in docs
|
Issue PAID IN FULL permit | | | 8/20/2018 | | DONE |
|
|
|
|