Final | 10/9/2018 | 10/10/2018 | 10/10/2018 | A | PASS |
Daryl DeGrange
|
|
|
Fixed Tub wire connections. Phone #: ###-#### Inspection requested via web by Douglas Hackney Swim hot tub in location within new addition to comply with required clearances for receptacles at time of final inspection, Hot tub on wheels. ceiling fan removed and planked off. Non conductive barrier between tub and exhaust fan. final ok
|
Final | 10/7/2018 | 10/8/2018 | 10/8/2018 | A | FAIL |
Daryl DeGrange
|
|
|
Code correction fixed Install GFCI breaker in sub panel for lighting. Phone #: ###-#### Inspection requested via web by Douglas Hackney NEC 314.4 Metal boxes shall be grounded and bonded Exposed conductors at point of entry of pool heater shall be relocated to inside of heater enclosure.
|
Final | 10/5/2018 | 10/5/2018 | 10/5/2018 | P | FAIL |
Eric Story
|
|
|
Trim Out - Final Go thru gate on side. New addition will be open. Phone #: ###-#### Inspection requested via web by Douglas Hackney Lights above pool shall be GFCI not AFCI protected
|
Electrical Rough-In | 8/24/2018 | 8/27/2018 | 8/27/2018 | A | PASS |
Tom Saunders
|
|
|
Code corrections fixed. Relocated outlet to outside. Pool to be moved for proper clearance from all other electrical boxes. Phone #: ###-#### Inspection requested via web by Douglas Hackney...ok to cover
|
Electrical Rough-In | 8/23/2018 | 8/24/2018 | 8/24/2018 | A | FAIL |
Rock A. Hudson
|
|
|
Addition at rear of House, enter thru iron side gate. Any questions..... call. Phone #: ###-#### Inspection requested via web by Douglas Hackney
680.27(C)- Heaters shall not be located with in 5' horizontal of inside edge of tub. 680.43(A)- All 120 volt 15 and 20 amp receptacle outlets shall be more than 6' from inside edge of hot tub. 680.43(B)- Lighting outlets located above or with in 5' horizontal of inside edge with GFCI protection shall not be with in 7'6" of waters edge. exception- recessed or surface mounted non-metallic or metallic with metallic isolated from contact permited below 7'6" if plastic or glass lense globe, GFCI protected, and damp location rated. 680.43(C)- Switches shall not be located with in 5' measured horizontal from inside edge of hot tub. Discussed exhaust fan located below deck shall not need horizontal clearance due to barrier however bonding and GFCI protection required.
|
Issue PAID IN FULL permit | | | 8/21/2018 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 8/21/2018 | | DONE |
|
|
|
This permit was created on the web by Douglas Hackney
|