Final | 12/13/2018 | 12/14/2018 | 12/14/2018 | A | PASS |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn Final ok
|
Rough-In Permanent Service | 9/10/2018 | 9/10/2018 | 9/10/2018 | A | PASS |
James Ady
|
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn rough in ok p/s u/g n ok
|
Issue PAID IN FULL permit | | | 8/24/2018 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 8/24/2018 | | DONE |
|
|
|
This permit was created on the web by Bob Glenn
|