Final | 12/13/2018 | 12/13/2018 | 12/13/2018 | P | PASS |
James Ady
|
|
|
Call for access code, thank you. Phone #: ###-#### Inspection requested via web by kim grundhauser. final ok
|
Rough-In Permanent Service | 9/19/2018 | 9/19/2018 | 9/19/2018 | A | PASS |
James Ady
|
|
|
call with any questions thank you Phone #: ###-#### Inspection requested via web by kim grundhauser rough in ok to cover p/s u/g n ok
|
Issue PAID IN FULL permit | | | 9/17/2018 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 9/17/2018 | | DONE |
|
|
|
This permit was created on the web by kim grundhauser
|