Final | 12/27/2018 | 12/28/2018 | 12/28/2018 | A | PASS |
Tom Saunders
|
|
|
Justin Phone #: ###-####... corrections made...ok to final
|
Final | 12/26/2018 | 12/26/2018 | 12/26/2018 | P | FAIL |
Tom Saunders
|
|
|
Justin Phone #: ###-####...
1..all 120 volt outlets in shop shall have GFCI protection 2..outside outlet HD/inuse cover needs installed properly
|
Electrical Rough-In | 11/5/2018 | 11/6/2018 | 11/6/2018 | A | PASS |
Tom Saunders
|
|
|
Justin Phone #: ###-####... rough in ok to cover
|
Electrical Rough-In | 10/31/2018 | 11/1/2018 | 10/31/2018 | A | PASS |
Daryl DeGrange
|
|
|
Justin Phone #: ###-#### Replacement of defective service panel interior, r/i ok
|
Electrical Rough-In | 10/3/2018 | 10/3/2018 | 10/3/2018 | P | CANC |
Rock A. Hudson
|
|
|
Justin Phone #: ###-#### Needed permanent service inspection.
|
Permanent Service | 10/3/2018 | 10/3/2018 | 10/3/2018 | P | PASS |
Rock A. Hudson
|
|
|
Justin Phone #: ###-#### p/s o/h n ok
|
Electrical Rough-In | 10/2/2018 | 10/3/2018 | 10/3/2018 | A | FAIL |
Rock A. Hudson
|
|
|
Justin-husband Phone #: ###-#### 250.92(A)- All non current carrying metal parts shall be bonded. Metal nipple installed in concentric holes not bonded.
|
Conference | 10/2/2018 | 10/2/2018 | 10/2/2018 | P | PASS |
Rock A. Hudson
|
|
|
Justin Phone #: ###-#### Discussed 200amp service and overhead clearence of service entrance conductors. Miscommumication with Idaho power on how easy it would be to get around tall shop and refeed house. Roof pitch on shop 3x12 suggested building a stand off on corner of shop and stay below roof to avoid above roof requirements. Has provided a grounding electrode system of ground rods 5'5" apart. Concrete encased electrode is provided on east wall that will be connected when framing complete on that wall. Discussed interior receptacle locations and types and required lights for interior and man doors.
|
Issue PAID IN FULL permit | | | 10/1/2018 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 10/1/2018 | | DONE |
|
|
|
This permit was created on the web by Justin Mace
|