Final | 5/20/2019 | 5/21/2019 | 5/21/2019 | A | PASS |
Mark Moncarr
|
|
|
please call 1/2 hour before Phone #: ###-#### Inspection requested via web by Charles Davis Ok final. Corrections made.
|
Final | 3/9/2019 | 3/11/2019 | 3/11/2019 | A | FAIL |
Rock A. Hudson
|
|
|
lock box code 2011 Phone #: ###-#### Inspection requested via web by Charles Davis 210.52(C)- For counter top areas in dining room area receptacle outlets shall be installed so that no point measured along wall line is more than 24" from a receptacle outlet. Island not set yet. 314.25- All boxes shall have covers. Furnace box mounted on side needs cover. 410.22- Luminaire boxes shall be covered. Light over sink hanging on wires.
|
Rough-In Permanent Service | 10/17/2018 | 10/18/2018 | 10/18/2018 | A | CANC |
Mark Moncarr
|
|
|
Lockbox on back door rail. Code 2011 Smoke dectors are to be wireless. Phone #: ###-#### Inspection requested via web by Charles Davis Added a RI inspection. No p/s. A new panel was installed in basement to replace existing.
|
Electrical Rough-In | 10/18/2018 | 10/18/2018 | 10/18/2018 | P | PASS |
Mark Moncarr
|
|
|
Ok cover basement and kitchen. All other locations fished in. Will check on final.
|
Issue PAID IN FULL permit | | | 10/12/2018 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 10/12/2018 | | DONE |
|
|
|
This permit was created on the web by Charles Davis
|