Final | 5/29/2019 | 5/29/2019 | 5/29/2019 | P | PASS |
Rock A. Hudson
|
|
|
Call the office ###-#### to have someone meet you there. If you have any questions please feel free to contact Clay ###-####. Thanks!! Phone #: ###-#### Inspection requested via web by Clayton Morgan Final ok
|
Final | 5/29/2019 | 5/29/2019 | 5/29/2019 | A | NH |
Rock A. Hudson
|
|
|
Call Clay ###-#### to meet you there. Thanks!! Phone #: ###-#### Inspection requested via web by Clayton Morgan House locked no access. Will recall. Contractor service calculation equals 115 amps, 125 amp main. OK.
|
Final | 5/23/2019 | 5/23/2019 | 5/23/2019 | P | FAIL |
Rock A. Hudson
|
|
|
It will be open. If you have any questions please feel free to contact Jason ###-####. Thanks!! Phone #: ###-#### Inspection requested via web by Clayton Morgan 110.22- label furnace disconnect. 210.52(C)- Counter top spaces located in pantry shall have receptacle outlets installed so that no point measured along wall line is more than 24" from a receptacle outlet. 314.25- All boxes shall have covers. Master bath switch and fan near shower. 406.5- Receptacles shall be securely mounted in place. kitchen counter near back man door. 230.79- Service disconnecting means shall not be less than calculated load to be carried. As noted prior... service calculation required for addition of hot tub.
|
Electrical Rough-In | 2/19/2019 | 2/20/2019 | 2/20/2019 | A | PASS |
Rock A. Hudson
|
|
|
There is a lock box on the back shop door, code 2020. If you have any questions please feel free to contact Luke ###-####. Thanks!! Phone #: ###-#### Inspection requested via web by Clayton Morgan Discussed with contractor service calculation results in approx. 140 amp minimum service needed for an additional branch circuit for hot tub. Contractor to increase service or prove calculation less than what exists by final. House rewire rough in ok cover
|
Electrical Rough-In | 2/18/2019 | 2/19/2019 | 2/19/2019 | A | FAIL |
Rock A. Hudson
|
|
|
Lock box is on the back shop door, code 2020. If you have any questions please feel free to contact CJ ###-####. Thanks!!! Phone #: ###-#### Inspection requested via web by Clayton Morgan 210.52(A)- No point measured along floor line shall be more than 6' from a receptacle oulet. living room north of entrance. 300.4- Where NM cable is run thru bored holes that do not maintain 1 1/4" from framing surface they shall be protected from damage by nail plates. * Service calculation needed for addition of hot tub.
|
Issue PAID IN FULL permit | | | 12/11/2018 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 12/11/2018 | | DONE |
|
|
|
This permit was created on the web by Clayton Morgan
|