Final | 3/5/2019 | 3/5/2019 | 3/5/2019 | A | PASS |
Rock A. Hudson
|
|
|
Smoke detectors are now AFCI protected. Phone #: ###-#### Inspection requested via web by Dan Hilke Final ok
|
Final | 3/2/2019 | 3/4/2019 | 3/4/2019 | A | FAIL |
Rock A. Hudson
|
|
|
Final was completed, but the permit was reopened so we could add a circuit for smoke detectors. If there is no one at the house, you can call myself or Jim Thorpe (###-####) for access to get in. Phone #: ###-#### Inspection requested via web by Dan Hilke 210.12- A ll outlets located in bedroom areas shall have AFCI protection. Smoke detectors.
|
Final | 2/26/2019 | 2/27/2019 | 2/27/2019 | A | PASS |
Eric Story
|
|
|
Phone #: ###-#### Inspection requested via web by Dan Hilke Final ok
|
Change Status to I | | | 2/27/2019 | | DONE |
|
|
|
change to ISS per Inspector-Eric
|
Final | 2/25/2019 | 2/26/2019 | 2/26/2019 | A | FAIL |
Rock A. Hudson
|
|
|
Please give me 30 minutes notice to get there and open up the house. Phone #: ###-#### Inspection requested via web by Dan Hilke 210.12- All outlets located in bedroom areas shall have AFCI protection, device shall be located where circuit receives its source. 250.140- Range and dryer circuits shall be 4-wire. Frames of appliance shall have bond with seperate equipment grounds. 314.25- All boxes shall have covers. Receptacles, switches, lights hanging on wires. 406.12- All 120 volt 15 and 20 amp receptacles shall be tamper resistant type. 408.4- Circuit directory shall be complete. 422.31- Appliances shall have a disconnecting means. DW, WH. 110.25 lockouts acceptable. * Explained only licensed wireman employed by him are allowed to perform work. * No smoke detectors installed. * To remove receptacle from west soffit and cord that is attached that runs to back of garage.
|
Fees Due Hold | 1/26/2019 | | 2/25/2019 | | DONE |
|
|
|
|
Telephone call | | | 1/14/2019 | | DONE |
|
|
|
Left voicemail for Dan to see what type of Misc. work is being donw. Scope of work shows it might be new branch circuits or branch circuit ext. ---update correct fixtures, inspection states they are doing all new wiring.
|
Electrical Rough-In | 1/7/2019 | 1/9/2019 | 1/9/2019 | P | PASS |
Eric Story
|
|
|
This is the small house (rectory) in the back corner of the church parking lot. Phone #: ###-#### Inspection requested via web by Dan Hilke Whole house re-wire ok Only walls opened was kitchen and bases opened
|
Issue PAID IN FULL permit | | | 1/7/2019 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 1/7/2019 | | DONE |
|
|
|
This permit was created on the web by Dan Hilke
|