Permit Information
Permit NumberELE19-00394
StatusFinaled
Name MULTI STATE ELECTRIC
Site Address 5123 N BUCKBOARD PL
Project Name 
Customer NumberN/A
ePlanReviewNo
Description
Addition: Recess the existing home runs into the floor joist, and provide wiring for a family room, bath room and utility room above the garage
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final3/18/20193/19/20193/19/2019APASS
DetailsMark Moncarr
Please call Brad with any questions Phone #: ###-#### Inspection requested via web by BRAD BAKER Ok final.
Electrical Rough-In2/12/20192/12/20192/12/2019PPASS
DetailsTom Saunders
garage lid...ok to cover
Electrical Rough-In2/1/20192/4/20192/4/2019APASS
DetailsTom Saunders
I walked the job and help make the corrections we should be ready for cover thanks Brad Phone #: ###-#### Inspection requested via web by Brad Baker....
rough in upstairs only
garage not approved for cover...general on job knows and will be contacting electrical contractor
Electrical Rough-In1/31/20192/1/20192/1/2019PFAIL
DetailsTom Saunders
Should all be open Phone #: ###-#### Inspection requested via web by Brad Baker...
1..NM cable ran parallel to framing members shall keep 1 1/4" distance from nearest edge of framing member 300.4(D)
2..where NM cable enters a junction box or device box a minimum of a 1/4 " of sheathing shall be in box- MULTIPLE LOCATIONS..314.17(C)
3..NM cable shall be secured/supported every 4 1/2 ft and within 12" of every cable entry into enclosure-334.30, within 8" of plastic boxes 314.17(C)
4..home runs need stapled within 12" of panel
Issue PAID IN FULL permit  1/30/2019 DONE
Payment received via Govolutions
Application received  1/30/2019 DONE
This permit was created on the web by Brad Baker