Final | 7/2/2019 | 7/3/2019 | 7/3/2019 | A | PASS |
James Ady
|
|
|
Phone #: ###-#### Inspection requested via web by Mike McCarrel Final ok
|
Final | 6/20/2019 | 6/21/2019 | 6/21/2019 | A | FAIL |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Mike McCarrel * Work not complete for area noted on BLD17-04429. 210.8(B)- All 15 and 20 amp 125 volt receptacle outlets installed in damp or wet locations shall have GFCI protection, 2-pole receptacles mounted on ceiling will be single receptacle type for heaters, no GFCI reuired. Ceiling mounted 15 or 20 amp 125 volt receptacles do not have a specific load. Any standard cord can be plugged into receptacle. Area below top of stalls being concidered damp location due to hose down area for cleaning.
|
Issue PAID IN FULL permit | | | 2/4/2019 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 2/4/2019 | | DONE |
|
|
|
This permit was created on the web by Jeremy Cloud
|
First Notice | 7/3/2019 | 7/3/2019 | | | |
James Ady
|
|
|
|