First Notice | 8/30/2019 | 8/30/2019 | 10/3/2019 | | DONE |
Tom Saunders
|
|
|
This permit finaled on the web by Harvey Reyna
|
Final | 8/29/2019 | 8/30/2019 | 8/30/2019 | A | PASS |
Tom Saunders
|
|
|
Nick will be on site for unit access. Final inspection for Units 135, 136, 233, 234, 235 and 236. This will complete this final phase of work. No further inspections needed after passing inspection. Phone #: ###-#### Inspection requested via web by Tod Lane... last 6 units...job complete...ok to final
|
Change Status to I | | | 8/15/2019 | | DONE |
|
|
|
Per phone call with Jana with Pacific Source Electric, final on 8/12 was only partial final, still need inspections on additional units.
|
Final | 8/10/2019 | 8/12/2019 | 8/12/2019 | A | PASS |
Eric Story
|
|
|
Re-inspection of Units 220, 221, 222, 223, 229 and 230 for partial final on these units. Phone #: ###-#### Inspection requested via web by Tod Lane corrections fixed final ok
|
Final | 8/8/2019 | 8/9/2019 | 8/9/2019 | A | FAIL |
Eric Story
|
|
|
Units 220, 221, 222, 223, 229 and 230 ready for final inspection. Nick prieto will be on site for access or questions. Phone #: ###-#### Inspection requested via web by Tod Lane Unit 221 not accessible Other units have exposed romex to Ptak units or no abrasion control on other side of flex
|
Final | 7/30/2019 | 7/31/2019 | 7/31/2019 | A | PART |
Eric Story
|
|
|
Electrical final on Units 120, 121, 122 and 123. Justin Carbonaro will be on site for access issues. Phone #: ###-#### Inspection requested via web by Tod Lane
Units as requested ok
|
Electrical Rough-In | 6/26/2019 | 6/27/2019 | 6/27/2019 | A | PASS |
Eric Story
|
|
|
Electrical rough-in inspection on Units 135, 136, 233, 234, 235 and 236. This will be the last set of rough-in inspections for this phase. Phone #: ###-#### Inspection requested via web by Tod Lane Units as requested ok to cover
|
Electrical Rough-In | 6/17/2019 | 6/18/2019 | 6/18/2019 | P | PASS |
Eric Story
|
|
|
Electrical rough-in inspection on Units 220, 221, 222, 223, 229, 230. David Forbes will be on site for questions and access. Phone #: ###-#### Inspection requested via web by Tod Lane Units as requested ok to cover
|
Electrical Rough-In | 6/10/2019 | 6/11/2019 | 6/11/2019 | P | PASS |
Eric Story
|
|
|
Electrical rough in on Units 120, 121, 122 and 123. David Forbes will be on site for access. Phone #: ###-#### Inspection requested via web by Tod Lane Units as requested ok to cover
|
Change Status to I | | | 6/4/2019 | | DONE |
|
|
|
Per Eric Story, final on other units not done, please reopen
|
Final | 5/29/2019 | 5/30/2019 | 5/30/2019 | A | PASS |
Eric Story
|
|
|
Final on last 3 units for this phase. Units 127, 129, 225. Justin will be available on site for access to units. Phone #: ###-#### Inspection requested via web by Tod Lane Final for phase ok
|
Final | 5/24/2019 | 5/24/2019 | 5/24/2019 | P | PART |
James Ady
|
|
|
Reinspection of Unit 137 for missing 2gang plate. Phone #: ###-#### Inspection requested via web by Tod Lane Correction made 137 final ok
|
Final | 5/22/2019 | 5/24/2019 | 5/24/2019 | A | PART |
James Ady
|
|
|
Final inspection on Units 137, 139, 238, 239. Phone #: ###-#### Inspection requested via web by Tod Lane 314.25. All boxes shall have cover plates. (137 missing 2gang cover in Shower room.) 139,238,239 Final ok
|
Final | 5/13/2019 | 5/14/2019 | 5/14/2019 | A | PART |
Eric Story
|
|
|
Trim inspection on Units 203, 206, 207, 208 and 209. Phone #: ###-#### Inspection requested via web by Tod Lane Units as requested ok
|
Final | 4/29/2019 | 4/30/2019 | 4/30/2019 | P | PART |
Eric Story
|
|
|
Final inspection on Units 105, 107, 108 and 109. Nick Prieto is on site for questions and access. Phone #: ###-#### Inspection requested via web by Tod Lane Units as requested partial final ok
|
Electrical Rough-In | 4/8/2019 | 4/9/2019 | 4/9/2019 | A | PASS |
Eric Story
|
|
|
Electrical rough-in on Units 127, 129 and 225. Call Nick Prieto for questions. Phone #: ###-#### Inspection requested via web by Tod Lane Units as requested ok to cover
|
Electrical Rough-In | 4/1/2019 | 4/2/2019 | 4/2/2019 | A | PASS |
Eric Story
|
|
|
Electrical rough in inspection on Units 137, 139, 238 and 239. Phone Nick Prieto for questions and access. Phone #: ###-#### Inspection requested via web by Tod Lane Units as requested ok to cover
|
Electrical Rough-In | 3/20/2019 | 3/22/2019 | 3/22/2019 | A | PASS |
Eric Story
|
|
|
Rough-in inspection on Units 203, 206, 207, 208, 209. Call Nick Prieto for questions. Phone #: ###-#### Inspection requested via web by Tod Lane Units as requested ok to cover
|
Electrical Rough-In | 3/14/2019 | 3/14/2019 | 3/14/2019 | P | PASS |
Eric Story
|
|
|
Re-inspect Units 105, 107, 108, 109. Phone #: ###-#### Inspection requested via web by Tod Lane Units as requested ok to cover
|
Electrical Rough-In | 3/13/2019 | 3/14/2019 | 3/14/2019 | A | FAIL |
Eric Story
|
|
|
Rough in inspection of Units 105, 107, 108 and 109. Nick Prieto will be on site for questions. Phone #: ###-#### Inspection requested via web by Tod Lane Type NM cable shall not be installed where subject to physical damage. 1 1/4 from framing member required
|
Issue PAID IN FULL permit | | | 2/28/2019 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 2/28/2019 | | DONE |
|
|
|
This permit was created on the web by Harvey Reyna
|