Final | 5/10/2019 | 5/10/2019 | 5/10/2019 | P | PASS |
Rock A. Hudson
|
|
|
HAYMAN HOUSE, PLEASE CALL TO SET UP TIME TO GET IN. Phone #: ###-#### Inspection requested via web by mike brown Areas of concern- 394.12- Existing knob and tube wiring has had insulation installed round conductors. Wiring method requires wiring to not be in contact with thermo-insulation to provent overheating. 406.4(D)- Grounding type receptacle outets installed on ungrounded branch circuits. Grounding type receptacles on ungrounded shall be GFCI protected or changed to 2 wire receptacles. Final ok
|
Permanent Service | 4/16/2019 | 4/17/2019 | 4/17/2019 | P | PASS |
Rock A. Hudson
|
|
|
IMPORTANT: CALL TOM BROWN (###-####) FOR ACCESS AND TIME Phone #: ###-#### Inspection requested via web by Bonnie Page Note concerns of knob and tube in contact with insulation on final. p/s u/g n ok
|
Issue PAID IN FULL permit | | | 3/14/2019 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 3/14/2019 | | DONE |
|
|
|
This permit was created on the web by Bonnie Page
|