Final | 7/24/2019 | 7/25/2019 | 7/25/2019 | P | PASS |
Rock A. Hudson
|
|
|
Please call Jim for access ###-#### Phone #: ###-#### Inspection requested via web by William Andrews Final ok
|
Final | 7/22/2019 | 7/23/2019 | 7/23/2019 | P | FAIL |
Rock A. Hudson
|
|
|
Please call Jim for access ###-#### Phone #: ###-#### Inspection requested via web by William Andrews 110.3- Open ground at receptacle in basement near fireplace. 210.8- All 15 and 20 amp 120 volt receptacle outlets located in unfinished basement area shall have GFCI protection. Unable to test all bathroom receptacles because some not working. 210.70- Neither switch located at stairway would operate light above. 300.15- all cables shall terminate in a box. Basement UF hanging. 410.10(A)- Rear patio light not mounted on surface so water will not enter wiring in box or wall. * Remove all abandoned 2 wire receptacles for patching.
|
Electrical Rough-In | 4/15/2019 | 4/16/2019 | 4/16/2019 | P | PASS |
Eric Story
|
|
|
Inspection requested via web by William Andrews Whole house re-wire ok to cover
|
Permanent Service | 4/16/2019 | 4/16/2019 | 4/16/2019 | P | PASS |
Eric Story
|
|
|
Inspection requested via web by William Andrews p/s o/h rec ok
|
Issue PAID IN FULL permit | | | 4/11/2019 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 4/11/2019 | | DONE |
|
|
|
This permit was created on the web by William Andrews
|