Final | 12/10/2019 | 12/11/2019 | 12/11/2019 | A | PASS |
Mark Moncarr
|
|
|
garage code 9277, thank you! Phone #: ###-#### Inspection requested via web by Darryn Coburn Ok final.
|
Electrical Rough-In | 8/29/2019 | 8/29/2019 | 8/29/2019 | P | PASS |
Mark Moncarr
|
|
|
This request is for a step light inspection. thank you! Phone #: ###-#### Inspection requested via web by Darryn Coburn Ok cover outside entry step lights.
|
Rough-In Permanent Service | 6/26/2019 | 6/27/2019 | 6/27/2019 | A | PASS |
Mark Moncarr
|
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn Corrections made. Talked to electrician about fitting used to attach GEC to ufer. Builder was supposed to leave ufer exposed before building front steps. The fitting used was a UL listed acorn type that once tightened the bolt shears off and makes a permanent connection. p/s u/g n ok
|
Rough-In Permanent Service | 6/10/2019 | 6/10/2019 | 6/10/2019 | P | FAIL |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn * No access to level 3. *No safety rails on exposed interior rails of upper floors. 210.52(A)- Stair rails on level 2 concidered wall space and will need receptacle outlets installed. 250.50- All available grounding electrodes shall be used for grounding electrode system. Ufer found at entry.
|
Electrical Rough-In | 6/10/2019 | 6/10/2019 | 6/10/2019 | P | PASS |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn Soffits only rough in ok cover
|
Issue PAID IN FULL permit | | | 5/2/2019 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 5/2/2019 | | DONE |
|
|
|
This permit was created on the web by Darryn Coburn
|