Permit Information
Permit NumberELE19-02492
StatusFinaled
Name SMITH NICHOLAS A
Site Address 1520 W DEWEY ST
Project Name 
Customer Number 
ePlanReviewNo
Description
Homeowner Online - Alteration or Repair: Run 50 amp circuit from existing panel on house to new subpanel on attached garage. Wire new circuits from subpanel for outlets and lights.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final9/17/20199/17/20199/17/2019APASS
DetailsMark Moncarr
I need to run my kids to school at 9am and have a doctor''s appointment at 9:30. If it works before then, great. If not, can we reschedule. Phone #: ###-#### Inspection requested via web by Nick Smith Ok final. 50a brkr changed to 60a for garage, panel labeled.
Electrical Rough-In9/10/20199/10/20199/10/2019PPASS
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Nick Smith
Discussed GFCI protection, Tamper resistant, NM supports not to exceed 4 1/2', 60 amp minimum feed to garage with more than 2 circuits. Wiring ran on surface of upper plates and down side of studs to boxes. Explained all below 8' needs guard strips to protect from physical damage.
Rough in ok.
Conference8/5/20198/5/20198/5/2019APASS
DetailsMark Moncarr
Trench is dug with conduit. I''d like to bury it but want the sign off first. Phone #: ###-#### Inspection requested via web by Nick Smith Ok cover trench from house to detached garage. 20"-24" deep.
Conference7/5/20197/8/20197/8/2019ADONE
DetailsMark Moncarr
Phone #: ###-#### Inspection requested via web by Nick Smith Discussed new power to garage, and the required circuits a long with protection.
Issue PAID IN FULL permit  7/5/2019 DONE
Payment received via Govolutions
Application received  7/5/2019 DONE
This permit was created on the web by Nick Smith