Final | 3/20/2020 | 3/23/2020 | 3/23/2020 | A | PASS |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Eric Schroeder Final ok
|
Final | 3/12/2020 | 3/13/2020 | 3/13/2020 | P | FAIL |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Eric Schroeder 210.12- AFCI protection needed for new bedroom outlets, smoke detectors and lights. 314.25- Out light front corner up high shall terminate in a complete cover. Wires hanging out with wire nuts. Secure water heater in wall box cover. 422.31- A disconnecting means shall be installed for hardwired appliances and water heater in bed mechanical room.
|
Electrical Rough-In | 9/20/2019 | 9/25/2019 | 9/25/2019 | A | PASS |
James Ady
|
|
|
Phone #: ###-#### Inspection requested via web by Eric Schroeder Rough in Kitchen, Master bath, main bath and misc lighting throughout
|
Issue PAID IN FULL permit | | | 9/20/2019 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 9/20/2019 | | DONE |
|
|
|
This permit was created on the web by Eric Schroeder
|