Final | 11/21/2019 | 11/22/2019 | 11/22/2019 | A | PASS |
Tom Saunders
|
|
|
Phone #: ###-#### Inspection requested via web by Greg Traudt..ok to final
|
Rough-In Permanent Service | 10/16/2019 | 10/16/2019 | 10/16/2019 | P | PASS |
Tom Saunders
|
|
|
Phone #: ###-#### Inspection requested via web by Greg Traudt...corrections made rough ok to cover p/s u/g new ok
|
Rough-In Permanent Service | 10/14/2019 | 10/16/2019 | 10/16/2019 | A | FAIL |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Greg Traudt 300.4- Where NM cable has been run thru bored holes that do not maintain 1 1/4" from framing surface they shall be protected from damage by nail plates. Front room corner all sides, under stair above door, upper stair wall, Master bath 12-2. *Missed wiring can in kitchen near nook. *Attic boxes trimmed at rough in.
|
Issue PAID IN FULL permit | | | 10/10/2019 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 10/10/2019 | | DONE |
|
|
|
This permit was created on the web by Greg Traudt
|