Final | 2/25/2020 | 2/26/2020 | 2/26/2020 | P | PASS |
Mark Moncarr
|
|
|
Phone #: ###-#### Inspection requested via web by Ryan Wilson Ok final. Corrections made.
|
Final | 2/20/2020 | 2/21/2020 | 2/21/2020 | A | FAIL |
Mark Moncarr
|
|
|
Homeowner will be on site at 830am Phone #: ###-#### Inspection requested via web by Ryan Wilson 1. West side of garage not GFI protected. 2. Recepts under stairs not GFI protected. 3. Connector needed for MC going into heating unit under stairs. 4. Recept front of garage not GFI protected. 5. Island recepts not tamper resistant. Notice posted on panel cover.
|
Rough-In Permanent Service | 11/6/2019 | 11/6/2019 | 11/6/2019 | P | PASS |
Mark Moncarr
|
|
|
Phone #: ###-#### Inspection requested via web by Ryan Wilson Ok cover. p/s u/g n ok
|
Issue PAID IN FULL permit | | | 11/6/2019 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 11/6/2019 | | DONE |
|
|
|
This permit was created on the web by Ryan Wilson
|