Final | 12/18/2019 | 12/19/2019 | 12/19/2019 | A | PASS |
James Ady
|
|
|
Homeowner will be on-site all day Phone #: ###-#### Inspection requested via web by Ashley Lanham 20A breaker installed on a 200A Panelboard. Breaker was installed in Middle of busing at time of inspection. 705.12B2(3)(b). 40 amp max when installed at opposite ends of busing. (Breaker may not be upsized unless relocated in panel) Final ok
|
Electrical Rough-In | 11/22/2019 | 11/27/2019 | 11/27/2019 | A | PASS |
James Ady
|
|
|
Area code 801. Phone #: ###-#### Inspection requested via web by Ashley Lanham listing only ok
|
Issue PAID IN FULL permit | | | 11/15/2019 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 11/15/2019 | | DONE |
|
|
|
This permit was created on the web by Ashley Lanham
|