Permit Information
Permit NumberELE19-04657
StatusFinaled
Name L & K ELECTRIC
Site Address 12136 W MESQUITE DR
Project Name 
Customer Number11130
ePlanReviewNo
Description
Addition: wiring new shed and addition on house, permanent service change
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final2/19/20202/20/20202/20/2020APASS
DetailsTom Saunders
Corbin Metcalf ###-#### Phone #: ###-#### Inspection requested via web by Samatha Solberg...corrections made...ok to final
Final2/17/20202/18/20202/18/2020AFAIL
DetailsTom Saunders
Corbin Metcalf ###-#### Phone #: ###-#### Inspection requested via web by Samatha Solberg...
1) exterior outlet needs heavy duty inuse cover..406.9(A)

2) panel in shed needs main breaker installed...discussed at rough in...abillity to have more then 6 swipes of hand...225.33
3) exterior lights need rated for damp location...keylesses not rated
Final2/12/20202/13/20202/13/2020AFAIL
DetailsEric Story
Justin ###-#### Phone #: ###-#### Inspection requested via web by Samatha Solberg
1) Tamper resistant receptacles required in shop
2) WR needed for outdoor recept
3) service recept required for mini split unit
4) GFCI trips free in shed
Permanent Service2/3/20202/3/20202/3/2020PPASS
DetailsTom Saunders
Corbin ###-#### Phone #: ###-#### Inspection requested via web by Samatha Solberg...p/s u/g reconnect ok
Electrical Rough-In1/6/20201/6/20201/6/2020PPASS
DetailsTom Saunders
Corbin Metcalf ###-#### Phone #: ###-#### Inspection requested via web by Samatha Solberg...
out building rough-in ok to cover...panel needs addressed-main breaker or panel with no more than 6 swipes of hand
Electrical Rough-In12/19/201912/19/201912/19/2019PPASS
DetailsTom Saunders
Justin Metcalf ###-####
Rough in inspection for addition. Phone #: ###-#### Inspection requested via web by Samatha Solberg...rough-in of addition complete...outbuilding scheduled later once rough-in done
Electrical Rough-In12/10/201912/10/201912/10/2019PPASS
DetailsTom Saunders
Partial wall rough in inspection. The existing wall will have to be called in for a separate inspection. Call Justin Metcalf for details ###-#### Phone #: ###-#### Inspection requested via web by Samatha Solberg...ok to cover exterior walls only of new addition...ceiling and removed wall area rough scheduled later time
Electrical Rough-In12/5/201912/6/201912/6/2019APASS
DetailsTom Saunders
Justin Metcalf ###-#### Phone #: ###-#### Inspection requested via web by Samatha Solberg...underground to shed ok to cover
Electrical Rough-In12/3/201912/4/201912/4/2019ANR
DetailsTom Saunders
Justin Metcalf ###-####
This inspection is just for the underground conduit ran from the house to the shed. Phone #: ###-#### Inspection requested via web by Samatha Solberg...trench not complete and pipe install not complete
Issue PAID IN FULL permit  12/3/2019 DONE
Payment received via Govolutions
Application received  12/3/2019 DONE
This permit was created on the web by Samatha Solberg