Final | 6/16/2020 | 6/16/2020 | 6/16/2020 | P | PASS |
James Ady
|
|
|
Bill *screened* Phone #: ###-#### corrections made final ok
|
Override - Parcel Holds | 6/16/2020 | 1/1/1900 | 6/16/2020 | | |
|
|
|
.
|
Final | 6/15/2020 | 6/15/2020 | 6/15/2020 | P | FAIL |
Rock A. Hudson
|
|
|
Bill *screened* Phone #: ###-#### Correction not complete. 110.3- In garage receptacle marked welder is rated for 30 amp 125 volt for recreational vehicle use only, 2-pole 30 labelled supplies power.
|
Override - Parcel Holds | 6/15/2020 | 1/1/1900 | 6/15/2020 | | |
|
|
|
.
|
Final | 6/10/2020 | 6/11/2020 | 6/11/2020 | A | FAIL |
Rock A. Hudson
|
|
|
Bill *screened* Phone #: ###-#### 110.3- Down patio switches not working as per instructions. 1 locks out rest. 210.12- All bedroom outlets shall have AFCI protection. Down switch for patio lights, master bed entry. 210.52(C)- Pantry counter top areas shall have receptacle outets installed so that no point on counter is more than 24" from a receptacle outlet. 408.4- Complete circuit directory- unable to locate 130 RV receptacle in garage, Light over tub blanked off.
|
Override - Parcel Holds | 6/10/2020 | 1/1/1900 | 6/10/2020 | | |
|
|
|
.
|
Rough-In Permanent Service | 1/18/2020 | 1/21/2020 | 1/21/2020 | A | PASS |
Mark Moncarr
|
|
|
Phone #: ###-#### Inspection requested via web by Rhonda Yoast Ok cover. p/s u/g n ok
|
Issue PAID IN FULL permit | | | 1/10/2020 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 1/10/2020 | | DONE |
|
|
|
This permit was created on the web by Rhonda Yoast
|