Permit Information
Permit NumberELE20-00271
StatusFinaled
Name GLENN ELECTRIC
Site Address 2959 S SHADY LN
Project Name 
Customer Number 
ePlanReviewNo
Description
Complete Installation (includes room count and per: Rough & Perm Service
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final5/15/20205/15/20205/15/2020PPASS
DetailsJames Ady
garage code 4224 Phone #: ###-#### Inspection requested via web by Troy Ballard final ok
Rough-In Permanent Service2/6/20202/6/20202/6/2020PPASS
DetailsJames Ady
Phone #: ###-#### Inspection requested via web by Troy Ballard corrections made rough in ok p/s u/g n ok
Rough-In Permanent Service2/5/20202/5/20202/5/2020AFAIL
DetailsRock A. Hudson
Phone #: ###-#### Inspection requested via web by Troy Ballard
300.4- Nail plates shall be installed to protect NM cable where ran thru bored holes that do not maintain 1 1/4" from framing surface. To photo. 314.25- All boxes shall have covers installed completely covering openings. Check all recessed can junction box covers. 1 missing over stairs, several with gaps to boxes including tall ceiling.
352.48- Fitting securing PVC underground service entrance conduit to meter not glued.
408.7- Unused breaker spaces shall be closed by approved means.
Issue PAID IN FULL permit  1/23/2020 DONE
Payment received via Govolutions
Application received  1/23/2020 DONE
This permit was created on the web by Troy Ballard