Final | 6/30/2020 | 6/30/2020 | 6/30/2020 | A | PASS |
Eric Story
|
|
|
Phone #: ###-#### Inspection requested via web by Hidajet Zahic Final ok
|
Rough-In Permanent Service | 3/30/2020 | 3/30/2020 | 3/30/2020 | P | PASS |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Hidajet Zahic Rough in ok cover p/s u/g n ok
|
Rough-In Permanent Service | 3/28/2020 | 3/30/2020 | 3/30/2020 | A | FAIL |
Rock A. Hudson
|
|
|
Phone #: ###-#### Inspection requested via web by Hidajet Zahic 110.3- Unable to verify listing of pan boxes used on outdoor lights. 110.3- An interior junction box shall be inplace as per manufacturers instruction of furnace. 300.4- Where NM cable is run thru bored holes that do not maintain 1 1/4" from framing surface they shall be protected from damage. 1- above east exterior door, 1- upstairs in hall to raised bed above window.
|
Issue PAID IN FULL permit | | | 3/12/2020 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 3/12/2020 | | DONE |
|
|
|
This permit was created on the web by Hidajet Zahic
|