Final | 8/11/2020 | 8/12/2020 | 8/12/2020 | A | FAIL |
Eric Story
|
|
|
They will be open. If you have any questions please feel free to contact Jason ###-####. Thanks!! Phone #: ###-#### Inspection requested via web by Clayton Morgan 210.12 AFCI protection required for all bedrooms Garage recept in-op
|
Rough-In Permanent Service | 6/1/2020 | 6/2/2020 | 6/2/2020 | A | PASS |
Rock A. Hudson
|
|
|
It will be open. If you have any questions please feel free to contact ###-####. Thanks!! Phone #: ###-#### Inspection requested via web by Clayton Morgan Rough in ok cover p/s o/h n ok
|
Rough-In Permanent Service | 5/29/2020 | 6/1/2020 | 6/1/2020 | A | FAIL |
Rock A. Hudson
|
|
|
It will be open. If you have any questions please feel free to contact Kaiden ###-####. Thanks!! Phone #: ###-#### Inspection requested via web by Clayton Morgan 110.3- Recessed can j-fox covers shall be installed tight to box. Up living rm, up bath. 250.68- Concrete encased connection shall remain accessible located at house behind door. 334.30 NM cable shall be scured with in 12" of south oudoor receptacle box.
|
Electrical Rough-In | 4/22/2020 | 4/22/2020 | 4/22/2020 | P | PASS |
Eric Story
|
|
|
This is for the underground. If you have any questions please feel free to contact Clay ###-####. Thanks!!! Phone #: ###-#### Inspection requested via web by Clayton Morgan U/G from Detached garage to house ok to cover
|
Issue PAID IN FULL permit | | | 4/22/2020 | | DONE |
|
|
|
Payment received via Govolutions
|
Application received | | | 4/22/2020 | | DONE |
|
|
|
This permit was created on the web by Clayton Morgan
|