INSP - Final | 3/4/1996 | 3/4/1996 | 3/4/1996 | P | PASS |
Pat Lass
|
|
|
03/04/96 336 - TOM IS VERY BUSY SO I GAVE THIS TO YOU....DIX final ok
|
INSP - Ele Rough-In/Perm Svc | 1/9/1996 | 1/10/1996 | 1/10/1996 | P | PASS |
|
|
|
9 RMS AC OK CORR MADE 100 A OH CORR MADE
|
INSP - Ele Rough-In/Perm Svc | 1/8/1996 | 1/8/1996 | 1/8/1996 | P | FAIL |
|
|
|
DISAP CORR 210-52-A RECEP SPACING LIV AND BEDROOM 370-20 BOXES TO BE SET OUT FUTHER, 110-14 COPPER AND ALUM IN SAME TERMINAL, 250-84 2 GROUND RODS 25 OHMS RESISTANCE
|
Issue PAID IN FULL permit | | | 1/8/1996 | | |
|
|
|
|
INSP - Ele Rough-In/Perm Svc | 1/4/1996 | 1/5/1996 | 1/5/1996 | A | CANC |
Pat Lass
|
|
|
01/04/96 336 - FIRE DAMAGE 9 ROOMS AC 100 AMPS This was given to Tom
|
Application received | | | 1/4/1996 | | |
|
|
|
|
Issue FEE-DUE permit | | | 1/4/1996 | | FEE |
|
|
|
|