Information based on query as of Sunday, July 21, 2024.
Permit Information
Permit NumberELE96-00938
StatusFinaled
Name POWER ELECTRIC
Site Address 1722 S COLUMBUS ST
Project NameELE871903
Customer Number 
ePlanReview 
Description
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Receive PAYMENT IN FULL  3/7/1997
INSP - Final2/10/19972/11/19972/11/1997AFAIL
DetailsJack Frank
02/11/97 315 - KEY HIDDEN UNDER FRONT DOOR MAT.. 14 failed corrections corrections created cor. an d $30.00 reinspection fee due posted NEC, Ar bathrooms, 210-52(d), 210-8(a)(1) bathroom in laundry area
Issue & PRINT FEE-DUE permit  2/11/1997
INSP - Final2/10/19972/10/19972/10/1997PFAIL
DetailsPat Lass
02/10/97 336 - REINSPECTION- JACK FAILED FINAL ON 01/28 KEY UNDER FRONT DOOR MAT- HOUSE VACANT no correction notice on job
INSP - Final1/27/19971/28/19971/28/1997AFAIL
DetailsJack Frank
01/28/97 315 - HOUSE EMPTY..KEY UNDER MAT 14 failed jf cor. postd NEC, garage and bath outlets 210-63(c) and disconnect for furnace in attic
INSP - Permanent service5/6/19965/6/19965/6/1996PPASS
DetailsJack Frank
05/06/96 315 - 53 ok jf 200a o/h res. rec.
INSP - Permanent service5/2/19965/2/19965/2/1996PNH
DetailsJack Frank
05/02/96 315 - ASAP PLEASE NH jf will try later in the day
INSP - Permanent service5/2/19965/2/19965/2/1996 FAIL
DetailsJack Frank
/ / 315 - 53 failed jf cor. posted NEC 250-70,71,72 needs bond bushing between meter and service panel and ground for other services
INSP - Ele Rough-In/Perm Svc4/24/19964/24/19964/24/1996PCANC
DetailsJack Frank
04/24/96 315 - 3 ROOM REMODEL talked to Frank of Power Electric will meet him 4/25/96 in the AM
Issue PAID IN FULL permit  3/26/1996
Application received  3/26/1996