DOC - Permit Expired | 4/21/2009 | 4/21/2009 | 4/21/2009 | P | PASS |
Dixie Fellows
|
|
|
building permit was expired
|
Random Inspection | 4/21/2009 | 4/21/2009 | 4/21/2009 | P | PEND |
Dixie Fellows
|
|
|
check site
|
Case Summary (ESC) | | | 2/25/2008 | | |
|
|
|
|
Case Summary (ESC) | | | 2/25/2008 | | DONE |
|
|
|
|
(F) Reprint permit | | | 2/8/2008 | | DONE |
|
|
|
|
(F) Reprint permit | | | 12/10/2007 | | DONE |
|
|
|
|
(F) Reprint permit | | | 10/9/2007 | | DONE |
|
|
|
|
Case Summary (ESC) | | | 10/9/2007 | | DONE |
|
|
|
|
Tracking Control | 10/2/2007 | 10/2/2007 | 10/2/2007 | P | DONE |
Aimee Hughes
|
|
|
Visited site per Steve Webb's request. No immediate concerns visible, all previous issues are still unaddressed.
|
Tracking Control | 9/24/2007 | 9/24/2007 | 9/24/2007 | P | DONE |
Aimee Hughes
|
|
|
Visited site per Steve Webb's request to inspect site for slope stability and trackout after heavy rains received over the weekend. Noticed some small rills beginning to form in the driveway about half way up the drive. There was a small amount of trackout onto Ginzel. The driveway seems to be fairly compacted at this point. No other issues are visible at this time.
|
Routing - Erosion and Sediment | 9/19/2007 | | 9/19/2007 | | DONE |
|
|
|
Completed RFP's for site restoration. Five out on 9/18 and one out today. Six Informal Bids with return date of October 1, 2007.
|
BMP Violation | 9/6/2007 | 9/17/2007 | 9/17/2007 | A | FAIL |
Steven Webb
|
|
|
Very minor amount of slope material mulch but not enough to stablize the problem. The slope was not prepared for the material as well. The debris fence and bale barriers have not been installed. No work has been performed on the driveway. Significant progress has not been completed.
|
Conference | 9/6/2007 | 9/6/2007 | 9/6/2007 | | DONE |
|
|
|
Letter to owner to print shop for mailing this a.m. The letter is being sent both general delivery and certified mail. Contents of the letter outlines required timeframe to respond, modify plan for driveway and to complete work on site to stablize site to reduce erosion.
|
Site Preparation | 9/5/2007 | 9/5/2007 | 9/5/2007 | | PART |
|
|
|
Inspected the site at 12:30 p.m after a rain event. Minor track out was observed onto Ginzel. Driveway had not been worked on, no measures were in place to reduce mud and dirt track out. Only change was placement of minor amount of wattle up above at draw area. No other BMP had been installed. Left a voice message for Ms Cloud, provide a status report of events.
|
BMP Violation | 8/30/2007 | 9/4/2007 | 9/4/2007 | | FAIL |
Steven Webb
|
|
|
Perform site inspection prior to the meeting later in the day. Inspected site at 7:30 a.m. no signs of any additional work being performed. No response or call backs from last weeks phone messages. Owner nor contractor has submitted a schedule outlining when the erosion and sediment control plan according to the Aug 21 Notice & Order will be completed. This schedule was requested last week. Placed a phone call to RP, no answer, I requested on the message to call me. Will follow up.
|
BMP Violation | 8/30/2007 | 8/30/2007 | 8/30/2007 | P | DONE |
Steven Webb
|
|
|
Site reviewed by J. Wylie of Public Works. Notice some minor amounts of materials on site. Materials could be used for installation of the debris fence and hay for barriers in the draw below the upper slope. Noticed that a drop inlet had been protected close to the driveway at Ginzel. Will follow up on progress.
|
Conference | 8/30/2007 | 8/30/2007 | 8/30/2007 | | DONE |
|
|
|
Received the modified driveway erosion control stablization plan from Lochsa Eng. (Ryan Carnie, PE). Myself and public works will review and make a determination on the proposal. Telephoned B. Davis but no answer, left message requesting the revised schedule for the stablization of the entire construction area per the August 21, Notice & Order. Also I had left the same message on the telephone yesterday but had not received a call back.
|
BMP Violation | 8/22/2007 | 8/29/2007 | 8/29/2007 | A | FAIL |
Steven Webb
|
|
|
Inspection of the construction site revealed that no work had been performed. Detailed scope of work was specified in the August 21Notice & Order. Ginzel had been swepted but no drop inlet protections were in place. Owner did not comply with requirements according to the Notice and Order. Will follow up.
|
Conference | 8/28/2007 | 8/28/2007 | 8/28/2007 | | DONE |
|
|
|
Received phone call from RP; Bill Davis on 4/27/07 at 4:10 p.m. Informed me that work will start on 8/28/07 to address esc issues as outlined on the 8/21/07 Notice & Order. He said he was not going to cover the driveway with the 4" of 3/4" minus. I informed him that full compliance to the Notice & Order is expected. Mr. Davis informed me that a revised driveway plan will be prepared by Ryan Carnie of Lochsa Eng. Work is expected to start until completed commencing on the 28th. Will follow up.
|
Conference | 8/23/2007 | 8/23/2007 | 8/23/2007 | | DONE |
|
|
|
Received telephone call from Kathleen Davis; Had not received Notice & Order. Informed her of the timeframe to commence work 8-29-07 by the end of the day. Work to include revised plan from Ryan Carnie, dated 8-9-07. Made additional copies of the plan available and myself to assist wherever I could. Stressed the key point is to start until complete on site and to stablize the site. Ms. Davis provide me another phone number, its in my working file. Will follow up
|
Conference | 8/20/2007 | 8/21/2007 | 8/21/2007 | P | DONE |
Steven Webb
|
|
|
Mailed out via certified mail and general mail Notice & order along with past two correction notices. Also, faxed a complete copy. Need to start work by end of the day on Tuesday, August 28, 2007. No answer on telephone call. Will follow up
|
BMP Violation | 8/20/2007 | 8/20/2007 | 8/20/2007 | P | FAIL |
Steven Webb
|
|
|
Time has expired on 1st and 2nd correction notices. No progress has been performed. Preparing Notice and Order. RP (B. Davis) left voice message on to ESC Manager that he is getting cost to implement ESC plan modification dated 8-9-2007. Notice and Order will allow five days to commence work or additional steps to stablize the site will be performed by Boise City. No answer on phone number to verbally inform Mr. Davis of the Notice and Order. Will follow up.
|
Tracking Control | 8/13/2007 | 8/16/2007 | 8/20/2007 | A | FAIL |
Steven Webb
|
|
|
No changes has occured on site.
|
BMP Violation | 8/13/2007 | 8/13/2007 | 8/13/2007 | P | FAIL |
Steven Webb
|
|
|
Failure to comply with correction notice dated August 2, 2007. Did not notify The City of Boise Erosion Control staff with the name of the certified contractor who will be stablizing the construction site. Unable to contact owner (K. Davis)one phone had been disconnected and other phone had a message that no incoming calls were allowed at owners request.
|
BMP Violation | 7/27/2007 | 7/27/2007 | 7/27/2007 | A | FAIL |
|
|
|
Visited site at 8:30 a.m...Temporary power pole has been installed, Stop Work notice has been removed from the job trailer window again and dig line has been marked with red flags and red paint. Pictures are on file and findings have been sent to Steve Webb, Amanda Horton and Jenifer Gilliland.
|
Conference | 7/24/2007 | 7/25/2007 | 7/25/2007 | A | DONE |
Steven Webb
|
|
|
At 10:30 a.m: Met with project RP, issued written correction notice with permit general conditions. C/Notice included time frame for compliance or further enforcement will occur. Re-posted 2nd stop work order, first one was removed over our request to not. Electrical work was performed over stop work. Informed contractor/RP both of these offenses are grounds for issuance of a citation. Also on site was Code Enforcement (M. Garner), B. Archabald and Terry Records as well as the RP, (B. Davis).
|
BMP Violation | 7/18/2007 | 7/19/2007 | 7/24/2007 | A | DONE |
Steven Webb
|
|
|
Talked to property owner and responsible person. Stop work still posted.
|
Conference | 7/20/2007 | 7/20/2007 | 7/20/2007 | | DONE |
|
|
|
Informed Bill Davis via phone message that I need to get a status report.
|
Conference | 7/17/2007 | 7/18/2007 | 7/18/2007 | A | FAIL |
Aimee Hughes
|
|
|
Stop work issued. No futher work allowed until conference with Steve Webb and Terry Records has been scheduled. There are significant erosion and drainage concerns on site. Have left several messages for RP and builder. No return call yet.
|
Conference | 7/17/2007 | 7/18/2007 | 7/18/2007 | A | FAIL |
Steven Webb
|
|
|
Issued Stop Work Order; Signed by Steve Webb and Terry Records. Needs owner to respond to us to have a meeting.
|
Conference | 7/18/2007 | 7/18/2007 | 7/18/2007 | | DONE |
|
|
|
Reviewed site with Building Division Manager (JG) and Special Operations (BA). Argreed steps are needed to address issues observed where site, slopes including road could result in serious problems, including dirt/mud/rocks leaving site which could cause bodily harm and/or loss of property. Will follow up with letter to owner if conference with owner as prievously requested not be granted.
|
Complaint Inspection | 7/13/2007 | 7/16/2007 | 7/17/2007 | A | PART |
Aimee Hughes
|
|
|
Responded to citizen complaint regarding erosion and slope failure concern. Left vm for builder and RP to discuss ESC plan. Meeting with Steve Webb and Terry Records on 7-18 to inspect site.
|
Complaint Inspection | 7/12/2007 | 7/12/2007 | 7/13/2007 | P | CANC |
Aimee Hughes
|
|
|
|
Case Summary (ESC) | | | 12/12/2006 | | |
|
|
|
|
Routing - Erosion and Sediment | 10/18/2006 | | 10/19/2006 | | PASS |
|
|
|
ESC plan approved with attached conditions. ESC plan was submitted before BLD to start grading for lot preparation.
|
Issue & PRINT permit SFD | | | 10/19/2006 | | DONE |
|
|
|
|
Application received | | | 10/18/2006 | | |
|
|
|
|