DOC - Permit Expired | 6/22/2010 | 6/22/2010 | 6/22/2010 | A | PASS |
Daryl Spivey
|
|
|
no activity........ds
|
Aging Inspection | 6/22/2010 | 6/22/2010 | 6/22/2010 | | PASS |
Daryl Spivey
|
|
|
|
Random Inspection | 4/21/2009 | 4/21/2009 | 4/21/2009 | P | CANC |
Dixie Fellows
|
|
|
check site...duplicate
|
General Inspection | 9/18/2008 | 9/19/2008 | 9/19/2008 | A | PASS |
Steven Webb
|
|
|
Inspection for Change Order #2. Scope of work for change order is completed.
|
Complaint Inspection | 7/29/2008 | 7/29/2008 | 7/29/2008 | P | DONE |
Clint A Smith
|
|
|
Cleaned up rock off of road that came off of the entrance of the driveway. CAS 460
|
Conference | 7/23/2008 | 7/23/2008 | 7/23/2008 | P | DONE |
Steven Webb
|
|
|
2:00 p.m: Walked site with contractor, presented scope of work. Will provide price quote.
|
General Inspection | 7/16/2008 | 7/22/2008 | 7/22/2008 | A | FAIL |
Steven Webb
|
|
|
Did not receive response from property owner within 10 days. Inspected site, no progress had been made on site for compliance to posted corrected notice.
|
General Inspection | 7/10/2008 | 7/10/2008 | 7/10/2008 | P | DONE |
Steven Webb
|
|
|
Posted correction notice, complete all needed items by end of the day on August 9th.
|
General Inspection | 7/3/2008 | 7/3/2008 | 7/3/2008 | A | PART |
Steven Webb
|
|
|
Toured site with J. Wylie: Inspection revealed areas that need maintanence or possible sediment could be released from the worksite.
|
General Inspection | 6/30/2008 | 6/30/2008 | 6/30/2008 | P | PART |
Steven Webb
|
|
|
Driveway in need of some minor maintance. Vegetation is dry but effective to reduce erosion from lot. Flat lot in need of mowing. Check dams could use some minor repairs.
|
General Inspection | 4/25/2008 | 4/28/2008 | 4/28/2008 | A | PART |
Clint A Smith
|
|
|
Check dams installed on slope and growth of vegitation is good on slope also. Check dams coming down access road are in need of maintenance. Need to be cleared of sediment from behind. CAS #460
|
Random Inspection | 2/27/2008 | 2/27/2008 | 2/27/2008 | P | PASS |
Steven Webb
|
|
|
Overall site looks good. Slopes are ok, vegetation appears to be holding, road ok, no track-out observed on Ginzel. Minor maintence could be performed.
|
Site Preparation | 2/8/2008 | 2/8/2008 | 2/8/2008 | A | PART |
Clint A Smith
|
|
|
D.I. maintenance needed on D.I. on N. Ginzel. Recommend slope stabilization at slope to the right of construction entrance. Maintain construction entrance after snow melt.
CAS #460 Erosion Control Inspector
|
(F) Reprint permit | | | 2/8/2008 | | DONE |
|
|
|
|
Random Inspection | 12/5/2007 | 12/5/2007 | 12/5/2007 | A | PART |
Steven Webb
|
|
|
Follow up: Overall the site is aging well. Signs of a few minor failures on the slopes and at the consruction entrance. Will continue to monitor.
|
Tracking Control | 11/13/2007 | 11/13/2007 | 11/13/2007 | P | DONE |
Aimee Hughes
|
|
|
Visited site to inspect status of stabilization measures. Some vegetation is coming up. PIctures are on file.
|
Random Inspection | 10/29/2007 | 10/29/2007 | 10/29/2007 | P | PASS |
Steven Webb
|
|
|
Inspected site for compliance. Ground FX were watering seeded area. Observed seed starting to grow through the mulch on slopes. Everything else looked good. Will follow up.
|
Conference | 10/22/2007 | 10/22/2007 | 10/22/2007 | A | PART |
Steven Webb
|
|
|
Routine inspection after Friday's .5 inch rain event. No signs of failure on slopes nor driveway. RP to install 2nd drop inlet protection.
|
Random Inspection | 10/19/2007 | 10/19/2007 | 10/19/2007 | P | DONE |
Aimee Hughes
|
|
|
Stopped by site to take pictures of completed site work. Pictures are on file.
|
Tracking Control | 10/16/2007 | 10/19/2007 | 10/19/2007 | A | PASS |
Steven Webb
|
|
|
FOLLOW UP INSPECTION: Project looks good. Completion of contract.
|
Site Preparation | 10/16/2007 | 10/16/2007 | 10/16/2007 | A | PASS |
Steven Webb
|
|
|
Contractor working on site--provided comments. Site conditions are improving.
|
Site Preparation | 10/5/2007 | 10/5/2007 | 10/5/2007 | P | DONE |
Steven Webb
|
|
|
Not site preparation but general. Received insurance certificate.
|
Routing - Erosion and Sediment | 10/5/2007 | | 10/5/2007 | | DONE |
|
|
|
ESC approved plan is the RFB prepared by Boise City in agreement to the site restoration plan submitted from Ryan Carnie, P.E. Lochsa Engineering. Contract # 08 CON 030 mailed to contractor (Ground-FX) on October 5, 2007. Issued Notice to Proceed on October 5, 2007.
|
Application received | | | 10/4/2007 | | |
|
|
|
|
Issue & PRINT permit SFD | | | 10/4/2007 | | DONE |
|
|
|
|