General Inspection ESC | 8/19/2010 | 8/19/2010 | 8/19/2010 | | DONE |
Clint A Smith
|
|
|
Moved to a site final.
|
DOC - Permit Finaled | 8/19/2010 | 8/19/2010 | 8/19/2010 | P | PASS |
Clint A Smith
|
|
|
Have implimented final stabilization measures with hydro-seeding and due to multiple phases later on to area of the project, the permit is finalled out.
|
General Inspection ESC | 8/4/2010 | 8/4/2010 | 8/4/2010 | | DONE |
Steven Webb
|
|
|
Conference with J. Wylie (Boise City P. Works): Discussion took place regarding assisting with Public Works inspector in performing weekly inspection during upcoming project. Inspections will be performed by Inspector 460 or 420.
|
General Inspection ESC | 7/20/2010 | 7/20/2010 | 7/20/2010 | | PART |
Clint A Smith
|
|
|
verbal to RP; On the simplot pond where hydro seeding has occured along the banks, The crust is broken up due to foot tyraffic. Recommended a sediment barrier alonng the water edge and also access control to miniumize foot traffic in that area.
|
General Inspection ESC | 7/5/2010 | 7/5/2010 | 7/6/2010 | | PASS |
Steven Webb
|
|
|
Dewatering swale and other misc areas have been sprayed with seed and mulch. Since this is a on going project the NOI will remain opens and monthly inspections will occur until at which time active construction commences, this according to Wendy L. from Boise Parks. Call was made to Guho regarding upcoming 36th street ped bridge project.
|
General Inspection ESC | 6/18/2010 | 6/18/2010 | 6/18/2010 | | CANC |
Clint A Smith
|
|
|
no tracking
|
Tracking Control | 6/3/2010 | 6/3/2010 | 6/3/2010 | A | FAIL |
Clint A Smith
|
|
|
Verbal to RP: Clean up all sediment tracking off of project area onto the public street. Must provide tracking control to miniumize any further tracking.
|
General Inspection ESC | 5/28/2010 | 5/28/2010 | 5/28/2010 | | CANC |
Clint A Smith
|
|
|
Aggraculture!
|
Random Inspection | 4/14/2010 | 4/14/2010 | 4/14/2010 | P | PART |
Clint A Smith
|
|
|
liner has been put in place at the storm water out in the east end of Quinns Pond where erosion has occured. Liner within the channel still needs maintenance to occur where it has degrated.
|
Random Inspection | 4/9/2010 | 4/9/2010 | 4/9/2010 | A | DONE |
Clint A Smith
|
|
|
See inspector 420 log.
|
General Inspection | 4/8/2010 | 4/9/2010 | 4/9/2010 | P | PART |
Steven Webb
|
|
|
Water clarity appears clean, liner is in need of maintenance, Quinn's pond has an area on the north bank which is eroding under the stromdrain outlet, south of the apartment complex. Ponds number 2 & 3 has limited holding capacity.
|
General Inspection | 4/6/2010 | 4/6/2010 | 4/6/2010 | P | PART |
Steven Webb
|
|
|
Water still being pumped and appears clean at discharge point. Liner continues to deteriorate.
|
General Inspection | 4/1/2010 | 4/1/2010 | 4/1/2010 | A | PART |
Clint A Smith
|
|
|
All seapage out of the channel has been filled. No repairs have been made on the channel liner. But water is turbidity does not appear to be turbid.
|
General Inspection | 4/1/2010 | 4/1/2010 | 4/1/2010 | P | CANC |
Clint A Smith
|
|
|
|
BMP Violation | 3/25/2010 | 4/2/2010 | 4/1/2010 | A | CANC |
Clint A Smith
|
|
|
|
BMP Violation | 3/18/2010 | 3/25/2010 | 3/25/2010 | A | PART |
Clint A Smith
|
|
|
Liner is still in need of repair. Additional tears have been found in the liner. Also at north end of channel seepage is coming out of the channel. Will re-inspect on 4/2/10AM.
|
General Inspection | 3/18/2010 | 3/18/2010 | 3/18/2010 | P | PART |
Clint A Smith
|
|
|
Due to the ruling of the point that the project pertains to ag. BMP's have not been maintained. Discharge into the north pont has a green shade from the water. channel needs to have attention brought to the 6mil plastic lining where tears and bubbling due to the high winds. Reported to Erosion Control manager with PDS over the findings. Will re-inspect on 3/25/10AM.
|
Conference | 3/9/2010 | 3/12/2010 | 3/15/2010 | P | DONE |
Steven Webb
|
|
|
With MacAlavin, Public Works and Parks, 2:00 P.M. It was agreed to accept the definition due to the nature regarding agr. that sediment may be allowed into Pond #2 and 3 but the discharge into Sand Creek needs to be within the State of Idaho WQS limits. Will inspect weekly.
|
General Inspection | 3/12/2010 | 3/12/2010 | 3/12/2010 | P | FAIL |
Clint A Smith
|
|
|
Corrections have not been made within the channal with the liner.
|
BMP Violation | 3/9/2010 | 3/10/2010 | 3/10/2010 | A | PART |
Steven Webb
|
|
|
Water discharge from Quinn's Pond into Pond Number 2 appears to be in compliance. Informed RP that liner repairs are still needed.
|
General Inspection | 3/9/2010 | 3/9/2010 | 3/9/2010 | P | FAIL |
Clint A Smith
|
|
|
None of the repairs have occured that have been indicated in the pervious inspections. Also have viewed that at the discharge point into the first pond, the clarity has become cloudy. Possibly organics and sediment from scouring of the pond edge at the point of discharge. Have notified the RP of the findings of the inspection. Explained to the RP to contact the ERosion Control Manager over a solution to miniumizescouring at the discharge point. Will keep inspecting on a daily basis.
|
Conference | 3/9/2010 | 3/9/2010 | 3/9/2010 | A | DONE |
Steven Webb
|
|
|
Met with J. Gilliland and P. Woods for general discussion of project: Discussions resulted in agreements: 1) Pond number one should be protected from sediment; 2) De-watering trench should be lined, inspected and repairs made if necessary, 3) Sample results for discharge if above background at Sand Creek will require additional steps to achieve compliance. Jenifer and Paul will attend the Friday meeting at the Train Depot with Steve W.
|
BMP Violation | 3/5/2010 | 3/8/2010 | 3/8/2010 | A | FAIL |
Clint A Smith
|
|
|
Areas of the channel are still inb need of repair. But due to the sampoling result of the turbidity reading the RP is in the thought that if the repair are made it could excalate the problems. But per BMC 8-17 all BMP must be maintained. Also this is the rule of the CGP. Will monitor the channel for further issues.
|
General Inspection | 3/5/2010 | 3/5/2010 | 3/5/2010 | P | FAIL |
Clint A Smith
|
|
|
Verbal to RP: Maintenance needs to occur on the channel liner due to the exposed areas of the channel. RP has informed me that they do not want to shut the pumps down and see if there is an issue thats need to be corrected by turbid discharge into the ponds or sand creek. I Explained that perventive maintenance is how the maintenance shouuld occur. Not fixing when an actual issue occurs. Will re-inspect on 3/8/10 am to see if perventive maintenance occured.
|
General Inspection | 3/3/2010 | 3/4/2010 | 3/5/2010 | P | CANC |
Clint A Smith
|
|
|
|
General Inspection | 3/3/2010 | 3/3/2010 | 3/3/2010 | P | FAIL |
Clint A Smith
|
|
|
Verbal to RP: Discovered failure within the dewatering canal. 1. To the north of the BRidge, there is one of the seams that has back wash coming out of it with turrbid water. 2. Where they have laid down a second layer of plastic, water has made its way underneath of the 1st layer. Un known if it has made its way under both layers. Required maintanence must occur prior to 3/5/10Pm. Will re-inspect on a daily basis until repairs have occured.
|
General Inspection | 3/1/2010 | 3/1/2010 | 3/1/2010 | P | CANC |
Clint A Smith
|
|
|
Completed by 420
|
General Inspection | 3/1/2010 | 3/1/2010 | 3/1/2010 | P | PASS |
Steven Webb
|
|
|
Water quality being discharged appears good, draw down appr. 8 feet to date.
|
General Inspection | 2/25/2010 | 2/26/2010 | 2/26/2010 | P | PASS |
Clint A Smith
|
|
|
|
General Inspection | 2/24/2010 | 2/25/2010 | 2/25/2010 | A | PASS |
Clint A Smith
|
|
|
Dischage from the active pump of the pond appears to be clean. Please refer Steve Webb for turbidity readings.
|
General Inspection | 2/24/2010 | 2/24/2010 | 2/24/2010 | P | PASS |
Steven Webb
|
|
|
Water is running in lined trench and appears visually to be clean. Liner is working well and no erosion was observed.
|
General Inspection | 2/23/2010 | 2/24/2010 | 2/24/2010 | A | PASS |
Clint A Smith
|
|
|
Discharge is clean by visual appearance. Did not see any turbid flows from any seams or tears within the lining of the channel. Will re-inspect on a daily basis.
|
General Inspection | 2/23/2010 | 2/23/2010 | 2/23/2010 | P | NR |
Steven Webb
|
|
|
De-watering not occurring. Inspector 460 will re-inspect Wed. 2/24
|
General Inspection | 2/22/2010 | 2/22/2010 | 2/22/2010 | P | FAIL |
Steven Webb
|
|
|
Dewatering is not occurring due to the fact that the contractor had shut down the pump to repair the liner. Recommended that a 20 mil liner would be best to use instead of 6 mil. It remains the responsibility of the contractor and Parks for erosion controls in place which will reduce erosion to the MEP. Will follow up.
|
General Inspection | 2/18/2010 | 2/19/2010 | 2/19/2010 | A | PASS |
Clint A Smith
|
|
|
All BMP's in good conditions. Discharge point looking like in good condition. No scouring of areas at discharge point as thought of as a concern.
|
Site Preparation | 2/17/2010 | 2/18/2010 | 2/18/2010 | A | PASS |
Clint A Smith
|
|
|
Approved the channel for the dewatering. As of 9:00am on 2/18/2010 Gave the 48hr notification for monitoring to occur. One area of concern is at the discharge point into the pond where the berry bushes are covering the bank, Made it aware to all parties to obsevre what occurs there and to keep a look out for any potentail bank erosion. Will inspect 2/19/10 AM.
|
Site Preparation | 2/17/2010 | 2/17/2010 | 2/17/2010 | P | FAIL |
Clint A Smith
|
|
|
Four areas of issues were found at the test run of the dewatering channel.
1. Side cut of the channel is to low. The edge needs to rise at least 12" in 2 locations.
2. Where the over lapping of the 8mil plastic is the seem need to be secured with achor pins on the bottom flap. Also weighted non erodible materail needs to be placed on top flap of the seam to minuimize backflow under the bottom flap. 3. Place additional boulders at the discharge point of the channel into the pond to slow down the velocity to pervent bank scouring. Will be having another test run on 2/18/10 at 8:30am.
|
General Inspection | 2/12/2010 | 2/16/2010 | 2/16/2010 | A | DONE |
Clint A Smith
|
|
|
Refer to inspector #420
|
General Inspection | 2/16/2010 | 2/16/2010 | 2/16/2010 | P | PART |
Steven Webb
|
|
|
Walked the dewater trench with MacAlvain (Dean), Walt B. (Boise City). Grading of the trench is almost complete. Made some general comments, including recommended to elevate the north side of the berm at the bend and to make sure that the liner is anchored down properly prior to testing the water flow. As well, reminded Dean to call Inspector 460 for a visual inspection prior to commencment of the water test. Gave Dean my card and informed him to call me if needed. Contractor hopes to test trench with water Wed. p.m. (2/17/10).
|
Site Preparation | 2/10/2010 | 2/12/2010 | 2/12/2010 | P | PART |
Steven Webb
|
|
|
Walk site with C. Smith: Reviewed site plan with Walt from McAlvain, not ready to approve the start of de-watering, pipe is connected to the pumps but trench construction is just underway. Reviewed pond #2 and 3, should be adequate volume to handle discharge. Inspector #460 will follow up on Tuesday, Feb. 16th. Reminded Walt that trench needs to be lined not bare soil.
|
Site Preparation | 2/12/2010 | 2/12/2010 | 2/12/2010 | P | DONE |
Clint A Smith
|
|
|
Refer to #420 inspection notes.
|
General Inspection | 2/9/2010 | 2/10/2010 | 2/10/2010 | A | DONE |
Clint A Smith
|
|
|
Went over with the G.C. that they must have a site prep inspection with a "PASS" prior to dewatering operations occur.
|
General Inspection | 2/2/2010 | 2/9/2010 | 2/9/2010 | A | CANC |
Clint A Smith
|
|
|
Moved until 2/10/10AM
|
Site Preparation | 2/8/2010 | 2/8/2010 | 2/8/2010 | | NR |
Clint A Smith
|
|
|
|
Conference | 2/5/2010 | 2/5/2010 | 2/5/2010 | A | DONE |
Steven Webb
|
|
|
Discuss water monitor requirements with Boise City Public Works who has been requested by Parks to assist in the monitoring requirements during de-watering of the pond: Provide Walt a copy of the permits conditions and reviewed the "special conditions" section. Walt will get back to me in regards to the discharge monitoring in the near future.
|
Site Preparation | 2/4/2010 | 2/4/2010 | 2/4/2010 | P | NR |
Steven Webb
|
|
|
Work has not commenced but I did leave the RP a voice mail regarding the responsibility to control any sub-contractors including utility contractors. Also, requested the RP return my call so a brief discussion over the outfall and the intentions of plugging this prior to starting the water transfer and to discuss the type of liner they intend to use for lining the water transfer ditch. More of a conference then a site preparation inspection.
|
Conference | 2/2/2010 | 2/2/2010 | 2/2/2010 | P | DONE |
Clint A Smith
|
|
|
Went over conditions with Wendy L. from parks and rec and Walter from MacCalvain Contsruction. explained what requirements need to occur prior, during and post construction. Prior to any dewaterinf a Site preperation inspection must be scheduled with the Erosion Control Dept. with the city to inspect and approved all BMP's pertaining to dewatering and construction activity. During Dewatering opperations Daily water samples are required with a weekly report submitted to Steve Webb with the city Erosion Control dept. Also prior to the structural fill occurs with the pond another site preperation inspection is required to be scheduled to inspect all BMP's and approved. Also a confrence is required to outline the phase of work. At the end of the project final stabilization must occur on all denuded soil per instustry standards. Will follow up with a site prep inspection once secheduled by the permitee or on 2/09/10.
|
Site Preparation | 1/28/2010 | 2/1/2010 | 2/1/2010 | P | CANC |
Clint A Smith
|
|
|
Will be doing a confrence with Wendy L. at 12pm on the 2nd of Febuary. Later a site prep inspection will occur.
|
Issue & PRINT to be Invoiced | | | 2/1/2010 | | DONE |
|
|
|
|
Routing - Erosion and Sediment | 1/28/2010 | | 1/28/2010 | | PASS |
Steven Webb
|
|
|
ESC plan approved along with the permit's attached conditions.
|
Telephone call | | | 1/27/2010 | | DONE |
Tisha Gallop
|
|
|
per revised esc application submitted 1/27/10 acreage disturbed went from 4 to 5 acres.
|
Application received | | | 12/28/2009 | | |
|
|
|
|