Information based on query as of Saturday, June 29, 2024.
Permit Information
Permit NumberESC14-00409
StatusFinaled
Name KENNETH R SCAGGS
Site Address 8739 W HACKAMORE DR
Project NameLANDMARK APARTMENTS
Customer Number 
ePlanReviewNo
Description
ESC site map and SWPPP submitted for entire apartment complex which has 4 fourplexes and therefore 4 BLD permits, each with their own ESC permit. BMPs include stabilized entrance, DI protection, concrete and construction waste management, and dust control as necessary. Site prep meeting required.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
General Inspection12/15/201412/15/201412/15/2014 PASS
DetailsAndy J. Long
Groundwork complete for parking lot, stormwater drainage and utitlies. Work is ongoing on interiors of Landmark 4-plexes and landscaping crew are currently on site working. ESC permit activity for Landmark will be covered under ESC14-00408; 409-411 finaled.

No violations.
DOC - Permit Finaled12/15/201412/15/201412/15/2014PPASS
DetailsAndy J. Long
General Inspection10/28/201410/28/201410/28/2014 PASS
DetailsAndy J. Long
No trackout to Hackamore. Workers parking on pavement. DI protection on access road storm drain. Permits posted. No corrections required at Landmark Apts.
General Inspection9/10/20149/10/20149/10/2014 PASS
DetailsAndy J. Long
Landmark Apartments are in progress. All 4 foundations are poured and concrete washout has been cleaned/removed. Will need to another washout when curbing/sidewalks are installed.

Fiber Filtrex wattle is in place at low edges of the perimeter. No sediment leaving site onto adjacent homes and businesses.

No trackout to Hackamore and contractors are parking on the pavement.

Permit posted. No corrections at this time.
General Inspection7/23/20147/23/20147/23/2014 PASS
DetailsAndy J. Long
Issue & PRINT permit COM  7/18/2014 DONE
Application received  5/14/2014  
Routing - Erosion and Sediment5/14/2014 5/14/2014 DONE
DetailsAndy J. Long