Site Final | 4/29/2016 | 5/3/2016 | 5/4/2016 | P | PASS |
Andy J. Long
|
|
|
get that DI bag out!
DI bag has been removed as requested. No other corrections. All permits finaled.
|
DOC - Permit Finaled | 5/4/2016 | 5/4/2016 | 5/4/2016 | P | PASS |
Andy J. Long
|
|
|
|
General Inspection | 4/28/2016 | 4/28/2016 | 4/29/2016 | | PART |
Andy J. Long
|
|
|
Site complete and stabilized.
Correction request -
- remove DI bag in storm drain install for sediment control
No other issues
|
General Inspection | 4/13/2016 | 4/13/2016 | 4/13/2016 | | PASS |
Andy J. Long
|
|
|
BLD permit finaled and hillside revegetation/stabilization bond has been issued.
WIP on landscaping. Will need to remove DI bag once landscape along driveway shoulders is complete.
|
General Inspection | 3/29/2016 | 3/29/2016 | 3/29/2016 | | PASS |
Andy J. Long
|
|
|
|
General Inspection | 3/14/2016 | 3/14/2016 | 3/14/2016 | | PASS |
Andy J. Long
|
|
|
Driveway is now paved. Home near completion but not yet landscaped. No trackout, no turbid discharge or evidence thereof. Storm drain in front of home has sediment filter bag installed.
|
General Inspection | 2/26/2016 | 2/26/2016 | 2/26/2016 | | PASS |
Evan Jenkins
|
|
|
WIP: no esc issues
|
General Inspection | 2/11/2016 | 2/11/2016 | 2/11/2016 | | PASS |
Andy J. Long
|
|
|
|
General Inspection | 1/27/2016 | 1/27/2016 | 1/27/2016 | | PASS |
Andy J. Long
|
|
|
WIP on vertical and interior. DI bag installed. No trackout tor discharges to Starview. No complaints received. Approved.
|
General Inspection | 1/12/2016 | 1/12/2016 | 1/12/2016 | | PASS |
Evan Jenkins
|
|
|
wip: no violations observed at time of inspection.
|
General Inspection | 12/28/2015 | 12/28/2015 | 12/29/2015 | | PASS |
Andy J. Long
|
|
|
No trackout. Permit sign is posted. DI bag installed. No earthwork at this time. No corrections.
|
General Inspection | 12/11/2015 | 12/11/2015 | 12/14/2015 | | PASS |
Andy J. Long
|
|
|
|
General Inspection | 11/26/2015 | 11/26/2015 | 11/27/2015 | | PASS |
Andy J. Long
|
|
|
|
General Inspection | 11/11/2015 | 11/11/2015 | 11/12/2015 | | PASS |
Andy J. Long
|
|
|
WIP. No trackout, permit sign posted and DI in front driveway is installed. Approved, no activity at time of inspection.
|
General Inspection | 10/27/2015 | 10/27/2015 | 10/27/2015 | | PASS |
Andy J. Long
|
|
|
WIP on frame. No significant trackout. Permit is posted. No recent complaints received. No corrections at this time.
|
General Inspection | 10/12/2015 | 10/12/2015 | 10/12/2015 | | PASS |
Andy J. Long
|
|
|
|
General Inspection | 9/25/2015 | 9/25/2015 | 9/25/2015 | | PASS |
Andy J. Long
|
|
|
WIP. Minimal trackout from unpaved slope driveway is being sweeping periodically. Workers parking on the street. No fugitive dust observed, working on the frame. Approved.
|
Complaint Inspection | 9/10/2015 | 9/10/2015 | 9/10/2015 | P | PART |
Andy J. Long
|
|
|
Dust complaint received by code enforcement...
Dust complaint occured during the foundation excavation, which is now complete. No dust at time of inspecion, concrete workers working on foundation.
Called builder Justin to discuss stabilized entrance and trackout controls. Currently no construction entrance and trackout and dust occurs when used.
Sewer tap is supposed to be scheduled for next week, I will wait to for completion of that but warned that rock entrance will be required if it can't be paved. Long, relatively steep, driveway slope with create problem during wetter months.
|
Tracking Control | 9/2/2015 | 9/3/2015 | 9/3/2015 | A | PEND |
Andy J. Long
|
|
|
Hard Rock construction working on sewer and water tap in, which is why no construction entrance. RP had crew sweep up dirt that had tracked out to Starview. Will return to assess other sediment controls needed once sewer/utility work is complete.
|
General Inspection | 9/2/2015 | 9/2/2015 | 9/2/2015 | | PART |
Andy J. Long
|
|
|
DI bag in front of project is installed and was recently maintained. Permit sign is posted at driveway
Sediment trackout occuring onto Starview. Need to install a stabilized construction entrance and sediment control BMPs upslope. No discharges occuring.
Message left with Hard Rock Construction RP, will wait for call back for corrections. Tracking control inspection scheduled.
|
General Inspection | 8/18/2015 | 8/18/2015 | 8/18/2015 | | PASS |
Evan Jenkins
|
|
|
No activity at time of inspection. No ESC issues observed
|
General Inspection | 8/3/2015 | 8/3/2015 | 8/3/2015 | | PART |
Andy J. Long
|
|
|
No activity at site in recent weeks. Some trackout and loose dirt in gutter in front of driveway needs sweeping. Adjacent DI and sediment bag installed. Permit is posted.
|
General Inspection | 7/17/2015 | 7/17/2015 | 7/17/2015 | | PASS |
Evan Jenkins
|
|
|
WIP: dust suppression has been successful since last complaint. Framing in progress
|
General Inspection | 7/2/2015 | 7/2/2015 | 7/2/2015 | | CANC |
Andy J. Long
|
|
|
|
Complaint Inspection | 6/17/2015 | 6/17/2015 | 6/17/2015 | P | FAIL |
Evan Jenkins
|
|
|
Dust Complaint
Recieved 2 calls from the same complantee house pertaining to dust being an issue on a new hillside SFH. Inspected the site which was a legitimate complaint. Disclosed to worker onsite and also Rob that dust suppression activities need to occur (watering) before anymore work can occur. will follow up tomorrow
|
Site Preparation | 6/11/2015 | 6/11/2015 | 6/11/2015 | P | PASS |
Evan Jenkins
|
|
|
Justin Phone #: ###-####
Permit Posted: Perimeter waddles installed and staked down. Approved for construction
|
Issue & PRINT permit SFD | | | 6/10/2015 | | DONE |
|
|
|
|
Application received | | | 8/21/2014 | | DONE |
|
|
|
Application submitted via PDS Online on Aug 21 2014 11:50AM
|