General Inspection | 6/28/2016 | 6/28/2016 | 6/28/2016 | | PASS |
Andy J. Long
|
|
|
Grading phase, utility, and private storm water system installation is complete and hotel structure exterior is finished. WIP on interior and landscaping around site. No further ESC inspections on this permit, for remainingwork and vertical construction, see ESC15-00180
|
DOC - Permit Finaled | 6/28/2016 | 6/28/2016 | 6/28/2016 | P | PASS |
Andy J. Long
|
|
|
|
General Inspection | 5/13/2016 | 5/13/2016 | 5/13/2016 | A | PASS |
Bob Reichert
|
|
|
looked ok
|
General Inspection | 5/10/2016 | 5/10/2016 | 5/10/2016 | | PART |
Evan Jenkins
|
|
|
BMP maintenance required from Fridays storm event
|
General Inspection | 3/25/2016 | 3/25/2016 | 3/25/2016 | | PASS |
Andy J. Long
|
|
|
WIP on hotel. All 4 stories now complete, parking lot with stormwater infrastructure and landscaping are complete. No trackout or discharges from site.
DI bag installed on Sunrise Rim near Applebees will need to be moved upon completion and after street/gutter sweeping.
Will request maintenance next inspection, has adequate capacity and no rips.
|
Aging Inspection | 2/4/2016 | 2/4/2016 | 2/5/2016 | | PASS |
Andy J. Long
|
|
|
WIP on frame. No trackout and no discharges from Holiday Inn site. Trash and materials is contained. Parking lot and landscaping are already installed
|
General Inspection | 12/2/2015 | 12/7/2015 | 12/7/2015 | A | PASS |
Andy J. Long
|
|
|
Follow up inpseciton after sweeping CN
Surrounding roads were swept and landscaping/stabilization of hotel parking lot & grounds is near completion. All private and MS4 inlets has sediment filter bag inserts installed. No new corrections at this time. Pasadena Street is much cleaner.
Once conditions are dry all DI bags should be checked for maintenance.
|
General Inspection | 12/2/2015 | 12/2/2015 | 12/2/2015 | P | PART |
Andy J. Long
|
|
|
DIs installed. No active discharges, no muddy trackout.
Verbal correction to RP Bob to have street sweeper on Pasadena now that trenching and landscaping are complete. Significant amount of loose dirt in roadway and gutter.
|
Tracking Control | 11/10/2015 | 11/12/2015 | 11/12/2015 | A | PASS |
Andy J. Long
|
|
|
WIP on paving parking lot today and tomorrow the Shosone and Sunrise Rim utility trenches will be asphalted.
DI bags on existing storm drains are installed and in good condition. Reqeusted that some mud near landscaping area (NE corner by Applebees) be cleaned and RP agreeed to send crew there today. No discharges or spills, next week will all hard surfaces installed there will be significantly less of a trackout problem.
Will continue to monitor.
|
Tracking Control | 9/9/2015 | 9/9/2015 | 9/9/2015 | P | PART |
Andy J. Long
|
|
|
Trackout to Shoshone Street from site occuring. Verbal correction to Project Manager Bob to sweep up trackout today and continue to sweep regularly. Initial pit run installed has been covered with some backfill, parking lot is scheduled to be paved in 3 weeks before wetter weather arrives. Newly installed and existing DIs have sediment protection installed. Water truck on site for compaction and also dust control.
1st violation noted at site. Will continue to monitor.
|
Site Preparation | 7/2/2015 | 7/6/2015 | 7/6/2015 | A | PASS |
Andy J. Long
|
|
|
Bob Phone #: ###-####
Permit sign posted. Surrounding DI bags are installed. Site grubbing and initial grading to start Wednesday. ESC site map located in job trailer. Discussed rules for fugitive dust control and sweeping up trackout.
Approved.
|
Issue & PRINT permit COM | | | 7/2/2015 | | DONE |
|
|
|
|
Application received | | | 6/25/2015 | | DONE |
|
|
|
Application submitted via PDS Online on Jun 25 2015 9:52AM
|