Permit Information
Permit NumberESC16-00159
StatusFinaled
Name JIM CONGER
Site Address 4450 E WARM SPRINGS AVE
Project NameDallas Harris Sub # 14
Customer Number 
ePlanReviewNo
Description
(DALLAS HARRIS ESTATES #14)To conduct excavation of approximately cubic yards of earth to prepare for a new residential subdivision (future single family dwellings). Plans approved by Jason Taylor, Public Works Department on with required conditions attached to plans and this case. No structure or building construction allowed under this permit. ESC16-00159 is to be issued with this permit. Per Jason Taylor - A bond is required to be posted prior to issuance of this permit,
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
General Inspection1/5/20181/5/20181/5/2018 PASS
DetailsAndy J. Long
All parcels in DHE phase #14 are complete. DHE phase #15 is still active (see ESC16-00489). Storm drain inlets will be audited this spring and shall be removed if remaining.

ESC permit for this phase is finaled.
DOC - Permit Finaled1/5/20181/5/20181/5/2018PPASS
DetailsAndy J. Long
General Inspection12/21/201712/21/201712/21/2017 PASS
DetailsMichael Zawacki
DIs on west side of road still protected. Streets free from trackout. Some wind blow garbage.
General Inspection12/6/201712/6/201712/6/2017 PASS
DetailsMichael Zawacki
Road is clean, still has DIs on west side, area to north being developed. Creek banks and area seeded and tackified. Free from windblown trash. Stockpile south west of area.
General Inspection11/21/201711/21/201711/21/2017 CANC
DetailsAndy J. Long
General Inspection11/6/201711/6/201711/6/2017 PASS
DetailsMichael Zawacki
General Inspection10/20/201710/20/201710/24/2017 PASS
DetailsMichael Zawacki
Area clean. No fugitive dirt.
General Inspection10/5/201710/5/201710/5/2017 CANC
DetailsAndy J. Long
General Inspection9/20/20179/20/20179/22/2017 CANC
DetailsAndy J. Long
General Inspection9/5/20179/5/20179/8/2017 CANC
DetailsAndy J. Long
General Inspection8/21/20178/21/20178/23/2017 CANC
DetailsAndy J. Long
General Inspection8/4/20178/4/20178/4/2017PPASS
DetailsAndy J. Long
MIllbrook was swept, DI bags on west side of road removed, and some trash picked up in the open area between Milbrook and Warm Springs Creek. Construction materials and equipment have been removed.

Need to sweep east side gutter of Milbrook, some trash remaining needs to be picked up. Alleyways still have some inlets with DI bags. Will notify Blackrock RP and check next inspection.
Complaint Inspection7/25/20177/25/20177/26/2017PFAIL
DetailsAndy J. Long
Corrections needed:

- clean up stockpile of landscaped gravel/rock in street in and gutter
- remove full trash can on east side of Millbrook. Pick up wind blown & scattered trash between street and Warm Springs Creek channel.
- remove all temporary DI bags from DHE #14 in streets and alleys except for on Millbrook
- inform concrete sub-contractor to relocate supply trailer away from fire hydrant.

Verbal Correction Request to Clint with Blackrock (formerly Tahoe)
General Inspection7/18/20177/18/20177/19/2017 PASS
DetailsMelissa Jannusch
WIP on SFHs
General Inspection7/3/20177/3/20177/3/2017 PASS
DetailsMelissa Jannusch
Windblown trash has been cleaned up. Trackout from stockpiles has been swept.
BMP Violation6/16/20176/16/20176/16/2017PPEND
DetailsMelissa Jannusch
RP Clint Wall got a new phone so the correction requests were not reaching him. I have recieved RP Clint's new phone number and requested the corrections. He is starting work on corrections currently. Will follow up monday.
BMP Violation6/8/20176/13/20176/16/2017ACANC
DetailsMelissa Jannusch
General Inspection6/2/20176/8/20176/8/2017PFAIL
DetailsMelissa Jannusch
No windblown trash has been removed from warmsprings creek across from 3149 millbrook.

DI bags at the South end of Shady wood have not been removed

Correction: clean trash from warmsprings creek. Remove DI bags

Follow up: Tuesday 6/13/2017

Left a message with RP Clint and with Joey of Tahoe Homes requesting corrections. Send picture of trash via text message to RP Clint.

This is the second failed inspection for the same correction request if the request is not completed by the next scheduled inspection escalation actions will be taken.

New correction: The small stockpile on millbrook needs a wattle around the perimeter or to be placed on a tarp so the sediment will not runoff into the stromdrains when it rains or become trackout. Requested correction to RP Clint. Follow up tuesday.
General Inspection6/2/20176/2/20176/2/2017PFAIL
DetailsAndy J. Long
Need to remove DI bags that full at south end of Shadywood. All homes are complete and stabilized and DI bags could cause flooding or break loose into system.

Lots of trash in Warm Springs Creek east of Millbrook projects by Tahoe Homes. Verbal correction request to RP Clint.
General Inspection5/23/20175/23/20175/23/2017 PASS
DetailsMelissa Jannusch
WIP on SFHs and clubhouse.
General Inspection5/8/20175/8/20175/10/2017 PASS
DetailsMelissa Jannusch
WIP on several SFHs. DI bags ok. Some trackout by homes that are in progress.
General Inspection4/20/20174/20/20174/20/2017 PASS
DetailsMelissa Jannusch
WIP on SFH. No excessive trackout. DIs are ok.
Conference4/20/20174/21/20174/20/2017ACANC
DetailsMelissa Jannusch
General Inspection4/5/20174/5/20174/5/2017 PASS
DetailsMelissa Jannusch
WIP on SFHs. DI bags ok. Little trackout.
General Inspection3/21/20173/21/20173/21/2017 PASS
DetailsMelissa Jannusch
No ESC issues. Bank not revegetated yet.
General Inspection3/6/20173/6/20173/6/2017 PASS
DetailsMelissa Jannusch
General Inspection2/17/20172/17/20172/17/2017 NR
DetailsMelissa Jannusch
Warm Springs Creek bank not stable on N side of parkcenter.
General Inspection2/1/20172/1/20172/6/2017 PASS
DetailsMelissa Jannusch
No corrections.
General Inspection1/2/20171/2/20171/4/2017 CANC
DetailsAndy J. Long
General Inspection12/16/201612/16/201612/21/2016 CANC
DetailsAndy J. Long
General Inspection12/1/201612/1/201612/1/2016 CANC
DetailsAndy J. Long
General Inspection11/16/201611/16/201611/18/2016 PART
DetailsAndy J. Long
No violations within subdvision.

Correction request to remove plastic sheeting from Warm Springs creek south of Parkcenter has still not fulfillied. Reinspection fees will start being applied.
General Inspection11/1/201611/1/201611/1/2016 PART
DetailsAndy J. Long
Multiple SFHs active at once. DIs have sediment protection and

Corrections needed:

- remove plastic sheeting used in Warm Springs Creek south of Parkcenter Blvd
- close access to Parkckenter from unfinished portion of Millbrook. Causing trackout on both sides sob.
General Inspection10/17/201610/17/201610/17/2016APART
DetailsAndy J. Long
WIP on SFHs in DHE #14. No trackout outside of subdivision or onto main streets. Alley ways are muddy in some places but will be swept upon drying. All storm drains have sediment filters installed.

Correction request:
- prevent exit from Milbrook to Parkcenter. No stabilized entrance and is starting to cause track out. Posted sign to use Brookridge exit and blocked road.

Developer also stated he would assist in blocking entrance, call Hunter and Tahoe RPs as well. Developer to have plastic sheet removed from creek on south side of Parkcenter.
General Inspection10/11/201610/11/201610/17/2016 CANC
DetailsAndy J. Long
General Inspection9/23/20169/23/20169/23/2016 PEND
DetailsAndy J. Long
SFH construction now in progress. Tahoe Homes and Hunter is in control of BMP maintenance for their activities.

Waiting for schedule for further Warm Springs Creek stabilization and temp BMP removal.

Correction request to Mr. Conger: remove plasic sheeeting used as a outfall dissipator on south side of Parkcenter.
Random Inspection9/7/20169/7/20169/7/2016PPEND
DetailsAndy J. Long
Need to remove temporary BMPs in creek...

Discussed with RP and Syman Company
General Inspection8/24/20168/24/20168/24/2016 PASS
DetailsEvan Jenkins
no issues observed at this time
General Inspection7/25/20167/25/20167/25/2016PPASS
DetailsAndy J. Long
Subdivision grading, road & utilitiy installation, and parcel prep complete in DHE #14. Silt fence along creek has been removed. Flat parcels do not have temporary stabilization, but not windblown dust or sediment runoff issues occuring.

Will need to re-seed the widened area of creek in fall and remove all temp BMPs installed (check dams, coffer dam and diversion tube, plastice at outlet.
BMP Violation6/30/20166/30/20166/30/2016PFAIL
DetailsAndy J. Long
Fugitive dust from site with no water truck control being used for the haul road where dump trucks are bringing in fill for the flood plain elevation requirements.

Multiple dust warnings at this site. Landscape crew also making dust.

Verbal CN to Jesse with CA to get their own water truck on site. HiGrade has water for DHE #15.
General Inspection6/24/20166/24/20166/24/2016PPASS
DetailsAndy J. Long
Streets and gutters now installed. Landscaping in progress. New inlets have sediment filter bags installed. No changes to Warm Springs Creek BMPs. May need to re-seed in Fall.

No corrections issued.
General Inspection6/1/20166/1/20166/1/2016PPASS
DetailsAndy J. Long
WIP installing curbing for roads. Utilities already installed. Some loose sediment at site entrances need to be swept up end of day. No fugitive dust observed, water truck on site.
General Inspection5/5/20165/5/20165/5/2016PPASS
DetailsAndy J. Long
Windblown trash from active sites in DH #13 that had collected along Warm Springs Creek has been picked up by Tahoe Homes and Hunter Homes as requested last Friday.

CA Paving on site working, no trackout, significant fugitive dust or other issues. Permit sign posted. Approved.
General Inspection4/14/20164/14/20164/14/2016PPART
DetailsAndy J. Long
Sewer and storm water infrastructure installed. Warm Springs Creek coffer dam and hardpipe is still installed to convey water over the recently widened creek. The creek bed has been hydroseeded to establish vegetation.

Minimal activity occuring at time of inspection, no trackout or discharges observed. No fugitive dust.

Need to work with Tahoe Homes and Hunter Homes to get windblown trash out of the creek area.

General Inspection3/10/20163/10/20163/10/2016PPASS
DetailsAndy J. Long
Inspection conducted to observe the phase 1 implementation of the dewatering/creek bypass plan at DHE #14.

Warm Springs Creek is dammed and water flows into a 12 " pipe that conveys the water over the disturbed and not yet stabilized creek bed that was widened before north of the existing box culvert. Water discharge out of the pipe is clear and system appears to be working well.

Syman Company will reinstall the silt fence to keep construction work and sediment out of the new creek bed.

Approved. Phase 2 for utilitiy/sewer installation to begin next week.

Issue & PRINT permit COM  3/10/2016 DONE
Additional plans submitted  3/9/2016 PASS
DetailsAndy J. Long
Dewatering plan submitted for review. Plan details two phases, one phase for work done in Warm Springs Creek to widen it for flood control and to cross under E. Parkcenter and second phase of dewatering for sanitary sewer excavation and installation. First phase will include damming the creek with washed rock and geotextile and pumping the water around the construction area south of the road and back into the creek. No turbidity testing is required will be performed but discharges/flows will be monitored visually and must not be turbid. Phase 2 will include 3 pumps to draw down water. A lined settling pond is to be built to and is designed to retain and settle water before disharging into an irrigation ditch that crosses under the road. A dewatering bag will be installed on the outlet of the hose before entering the pond to allow for additional treatment and velocity dissipation. Plans approved and retained City of Boise ESC division.
Permit Ready to Issue  3/9/2016 DONE
Fees due DO NOT REISSUE
Telephone call  3/9/2016 DONE
Left a message for Jesse that the paper work he turned into Andy was ready to be picked up and the fee amount that is due
BMP Violation3/7/20163/7/20163/7/2016PPEND
DetailsAndy J. Long
Warm Springs Creek work was uncompleted and unstabilized before re-graded channel area started to flow after weekend rains. Runoff water passing through work area picks up loose sediment and becomes turbid.

Corrections currently in progress. Looking into diversion options and more filtering check dams downstream from work area.

No sewer work requiring dewatering is approved until plan for fixing this situation is presented.

Slight plume of turbid water was visible in Boise River where Warm Springs Creek joins across for Barber Park. Viewed at approximately 11 AM 3/7/2016; investigation and corrective actions still in progress.
Tracking Control3/4/20163/7/20163/7/2016APART
DetailsAndy J. Long
Trackout being cleaned up and entrance is blocked during the muddy condtions....
Tracking Control3/2/20163/3/20163/4/2016PCANC
DetailsAndy J. Long
rescheduled
General Inspection3/2/20163/2/20163/2/2016PPART
DetailsAndy J. Long
Grading work in progress. No fugitive dust and no major trackout.

Correction needed: Construction entrance needs maintenance and the correct size rock if hauling is going to occur.

Investigated the work occuring in Warm Springs Creek channel. The work is detailed and approved in the grading plans and is widening the channel to 8 feet leading up to rip rapping it under the road culvert. Work appears to have remained within the designated area of disturbance.

This creek will need stabilization and erosion control as soon as possible as there is no diversion for runoff and rain water in the Warm Springs Creek. The creek is flowing at Barber Road but soaks into the groud approximately 1/4-1/3 mile upstream of the construction in the horse/cow pasture.
Site Preparation2/10/20162/12/20162/12/2016APASS
DetailsAndy J. Long
Follow up site prep to inspect BMPs...

Rock construction entrance installed. ESC permit sign and SWPPP box located at entrance. Silt fence along desgnated section of Warm Springs Creek is installed with a buffer zone along the banks.

Approved. WIP.
Site Preparation2/10/20162/10/20162/10/2016APEND
DetailsAndy J. Long
Walk through conducted with Syman Company contact Andy. Perimeter BMPs and silt fence protection for Warm Springs Creek is to be started this afternoon and completed tomorrow. Buffer is also to be provided.

Crew on-site starting initial grading and preping area for construction entrance. Verbal notice to foreman to have proper entrance installed ASAP before any loading/unloading activities.

Permit sign posted and permit is issued and paid for. No violations at time of inspection, but site is not yet fully ready. Will re-inspect Friday post BMP installation.
Issue & PRINT permit COM  2/10/2016 DONE
Application received  2/4/2016  
General Inspection1/17/20171/17/2017   
DetailsMelissa Jannusch