Information based on query as of Wednesday, July 3, 2024.
Permit Information
Permit NumberESC16-00436
StatusFinaled
Name JASON JONES
Site Address 2950 E PARKCENTER BLVD
Project NameArboretum at Barber Station
Customer Number 
ePlanReviewNo
Description
BUILDING #2: Arboretum at Barber Station is a 162 unit apartment complex consisting of 3 building on a 4.07 acre site. Buildings 1 & 2 are podium structures with 4 stories of apartments in Type 5A wood construction over 1 story of Type 1A post-tension concrete structure. Building 3 is a two story Type 5B wood construction with 1 level of apartment units over tenant amenities.

A separate structural podium permit application has been filed for Buildings 1 and 2.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Site Final11/28/201711/28/201711/28/2017APASS
DetailsAndy J. Long
Building complete. Parking lot for Arboretum now paved and stormwater facilities connected. Concrete washout onsite for remaining work occuring on building 1 and 2. No trackout or discharges. Inspected 11/27 PM
General Inspection11/21/201711/21/201711/21/2017 CANC
DetailsAndy J. Long
General Inspection11/6/201711/6/201711/6/2017 PASS
DetailsMichael Zawacki
Installing pervious pavers at entrance and in parking lot. Majority of exterior work complete. Installing facade and working on interiors. Talked to foreman last week and is doing daily garbage pickups. Site free of tackout and runoff. Perimeter in place around greenbelt.
General Inspection10/20/201710/20/201710/23/2017 CANC
DetailsAndy J. Long
General Inspection10/5/201710/5/201710/5/2017 CANC
DetailsAndy J. Long
General Inspection9/20/20179/20/20179/22/2017 CANC
DetailsAndy J. Long
General Inspection9/5/20179/5/20179/8/2017 CANC
DetailsAndy J. Long
General Inspection8/21/20178/21/20178/22/2017 CANC
DetailsAndy J. Long
General Inspection8/4/20178/4/20178/4/2017 PASS
DetailsAndy J. Long
Site Preparation7/19/20177/20/20177/20/2017APART
DetailsMelissa Jannusch
Interior trackout not cleaned or new trackout has been created. Trash is okay.
General Inspection7/14/20177/18/20177/19/2017PFAIL
DetailsMelissa Jannusch
Meet on site with GC Mike. Wattles look good. Need to finish cleaning few remaining trash pieces to pass inspection.
Corrections requested: finish cleaning trash. Sweep up interior trackout. Follow up scheduled for tomorrow morning.
General Inspection7/13/20177/13/20177/14/2017 PART
DetailsMelissa Jannusch
DI bags ok
Wattles need to be installed along north side
To pass Tuesdays inspection ALL trash along north side of site needs to be cleaned up. Requested corrections to RP and GC. follow up tuesday
General Inspection6/28/20176/28/20176/28/2017PPASS
DetailsMelissa Jannusch
Dewatering for pool: dewatering water is entering the sand and grease inceptor and then discharged into the sediment pond. All water is remaining onsite.

The fence is still broken but no longer obstructing the green belt.

Re installation of BMPs along fence perimeter is still needed. Wattles or silt fence would be okay.
General Inspection6/20/20176/20/20176/21/2017 PART
DetailsMelissa Jannusch
Respond to corrections written in the SWPPP inspection reports. Fix silt fence and construction fence on site. Clean trackout in the entrance. Trash containment has improved. Continue to pick up trash regularly. Flood water is receding. Pick up any construction trash that has floated into wetland area during flooding.
General Inspection6/5/20176/5/20176/6/2017 PART
DetailsMelissa Jannusch
Fence needs repairs still
Windblown trash in pond
Continue sweeping
Dumpster ok
Site needs a trash pick up. Bottles, paint cans and other trash are littered around the site.
Talked with project manager about corrections.
Dewatering has not started yet. Project manager will call for an inspection when dewatering starts.
General Inspection5/19/20175/19/20175/19/2017PPART
DetailsMelissa Jannusch
Silt fence has still not been repaired. No sediment moving offsite. No trackout. Water is rising.
General Inspection5/10/20175/10/20175/10/2017 PART
DetailsMelissa Jannusch
De-watering operation has not started yet. Corrections requested: pickup trash, sweep trackout at entrance.
General Inspection4/25/20174/25/20174/28/2017 PEND
DetailsMelissa Jannusch
Silt fence needs repairs where trenching is occurring. The perimeter chain link fencing needs repair as well. The water has risen since the last inspection.
General Inspection4/10/20174/10/20174/11/2017 PASS
DetailsMelissa Jannusch
WIP. SWPPP inspections are up to date. Water from high river flows is flowing through corner of the site. Ensure no pollutants are entering this area and being discharged into river water. Two concrete washout nearly full third is ok. Uncovered containers with unknown materials and rain water are uncovered. Dispose of properly and potentially cover if any pollutants are contained in barrels.
Corrections requested: Pick up wind blow trash around perimeter fencing. Repair silt fence. Around perimeter. Clean green belt where fence was run into.


General Inspection3/24/20173/24/20173/24/2017 PASS
DetailsMelissa Jannusch
WIP. No trackout, trash contained, concrete washout ok. Water level high on the NE side of the site. No corrections requested.
General Inspection3/9/20173/9/20173/9/2017 PASS
DetailsMelissa Jannusch
SWPPP is up to date. Trackout has been cleaned up. Small push electric sweeper is on site and used when trackout occurs. Minor corrections are noted in SWPPP and action to fix them underway. Corrections include concrete washout maintenance, slight trackout onto greenbelt, waste containers. Trash around site has been picked up.

General Inspection2/22/20172/22/20172/23/2017 CANC
DetailsMelissa Jannusch
See ESC15-01579
General Inspection2/7/20172/7/20172/8/2017 PASS
DetailsMelissa Jannusch
See ESC 15-01579
General Inspection1/23/20171/23/20171/23/2017 DONE
DetailsMelissa Jannusch
See ESC15-01579
General Inspection1/6/20171/6/20171/10/2017 CANC
DetailsAndy J. Long
General Inspection12/22/201612/22/201612/29/2016 PASS
DetailsAndy J. Long
Vertical construction in progress. No trackout or discharges. No loose trash or construction wrappings outside site perimeter.
General Inspection12/7/201612/7/201612/8/2016 PART
DetailsAndy J. Long
Inspection completed 12/7. No trackout, discharges, and BMPs are installed.

Corrections needed:
- silt fence repair or alternate BMP desingnated
- need to pick up loose trash and litter around site.

See Arboretum main permit for addition info. ESC15-01579
General Inspection11/22/201611/22/201611/23/2016 PART
DetailsAndy J. Long
see main permit ESC15-01579 for corrections. No trackout, discharges or fugitive dust.

- pick up trash around site
- repair damaged silt fence sections on west side of site.
General Inspection11/4/201611/4/201611/4/2016 PASS
DetailsAndy J. Long
Silt fence perimeter installed and in good condtion. No significant trackout, no discharges observed. No windblown trash; spill prevention practices implemented in staging areas. No corrections requested for the Arboretum projects (3 buildings, 1 site permit)
General Inspection10/20/201610/20/201610/20/2016 PASS
DetailsAndy J. Long
Vertical construction in progress at Arboretum project. 3 seperate buildings with 3 ESC permits, and one main site ESC permit issued for grading and utilitiy installation, see ESC15-01579.

Silt fence perimeter is in tact, no breaches or sediment runoff to Greenbelt path. No trackout from site, designated parking for the 60+ employees is across street to limit traffic. MS4 inlets on both sides of road have filter bags installed with good capacity remaining. Trash and materials contained on site. Concrete washout bins in several locations provided.

Observed pollution prevention on site with secondary containment storage for concrete form oils, diesal gas containers, and spill pans under neath porta-pots.

Approved.
Permit Ready to Issue  8/16/2016 DONE
Issue & PRINT permit COM  8/16/2016 DONE
Application received  3/31/2016 DONE
Application submitted via PDS Online on Mar 31 2016 4:48PM