Information based on query as of Friday, June 28, 2024.
Permit Information
Permit NumberESC17-00304
StatusFinaled
Name JOSHUA FOLGER
Site Address 7997 W FRANKLIN RD
Project NameLongHorn Steakhouse
Customer Number 
ePlanReviewNo
Description
See BLD for project description; fugitive dust during demolition phase required. Protect surrounding storm drain inlets. Protect existing perimeter curbing and vegetation. Limit trackout and do not leave uncovered loose dirt stockpiles on paved areas in order to prevent exposure to stormwater. ESC site preparation inspection required.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
General Inspection1/4/20181/4/20181/5/2018 CANC
DetailsMichael Zawacki
DOC - Permit Finaled1/5/20181/5/20181/5/2018PPASS
DetailsMichael Zawacki
Issue & PRINT permit COM  6/16/2017 DONE
Routing - Erosion and Sediment4/5/2017 4/5/2017 PASS
DetailsAndy J. Long
ESC plan approved. Site preparation/pre-construction inspection required. Need to designate valid RP for project.
Application received  3/21/2017 DONE
Application submitted via PDS Online on Mar 21 2017 2:35PM