Permit Information
Permit NumberESC17-00422
StatusFinaled
Name THOMAS CALLSEN
Site Address 2770 S VISTA AVE
Project NameICCU Vista Branch
Customer Number 
ePlanReviewNo
Description
The project is a financial institution that will be constructed in a C-2D zone. The project is 12,823 Sq. Ft. and will be sprinkled and constructed with Type IIB construction. BMPs: silt fence, SCE, DI protection.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Site Final9/27/20189/27/20189/27/2018PPASS
DetailsAndy J. Long
DI bags on Vista and Canal have been removed as requested. ESC permit conditions satisfied. Permit finaled.
Site Final9/20/20189/20/20189/20/2018ANR
DetailsAndy J. Long
Project complete, site is landscaped and onsite stormwater system is operational and drainage retained onsite. No loose dirt or materials left behind.

Correction need to receive ESC site final:

- remove temporary stormdrain drop inlet sediment bags installed for project on the NE and SW corners of Vista and Canal.
General Inspection8/6/20188/6/20188/6/2018 PASS
DetailsAndy J. Long
Project near completion. No immediate corrections, just will need to remove all temporary BMPs (storm drain inlet protection at Vista and Canal) and clean up any loose trash around perimeter before ESC site final approval
General Inspection6/21/20186/21/20186/21/2018PCANC
DetailsAndy J. Long
General Inspection6/19/20186/19/20186/19/2018 PASS
DetailsMichael Zawacki
Site is clean and contained. ACHD is doing work at corner of vista and canal.
General Inspection5/2/20185/2/20185/2/2018PPASS
DetailsMichael Zawacki
Perimeter controls and entrance in place. No dirt is leaving site. Mortar mixer is in secondary containment. No issues with site.
General Inspection3/20/20183/20/20183/20/2018PPASS
DetailsMichael Zawacki
Site contained. Good rock exit on Canal, no trackout. Perimeter control intact.
General Inspection3/2/20183/2/20183/2/2018PPASS
DetailsMichael Zawacki
Construction entrance to Canal being used. Will need to monitor for trackout, site is muddy. DIs and silt fence still in place.
Random Inspection2/5/20182/5/20182/5/2018PPASS
DetailsAndy J. Long
No trackout or discharges from. Construction entrances installed as well as MS4 sediment protection.
Random Inspection1/25/20181/25/20181/25/2018PPASS
DetailsMichael Zawacki
WIP on steel shell. Entrance still in place and road free from track out. Perimeter silt fence installed and still standing. DI installed and clean.
Tracking Control11/27/201711/27/201711/27/2017PPART
DetailsAndy J. Long
New construction entrance is installed with lining underneath angular rock. Entrance is still compacted and will need regular maintenance during heavy traffic.

Still need to install inlet protection on SW corner of Vista and Canal as requested.

No work or construction occuring at time of inspection.
Tracking Control11/22/201711/24/201711/27/2017ACANC
DetailsAndy J. Long
Tracking Control11/22/201711/22/201711/22/2017AFAIL
DetailsAndy J. Long
Significant trackout to Canal and south bound Vista due to heavy dump truck traffic unloading foundation backfill. Original rock entrance is compacted too much and no lining was installed under rock.

Sweeper unit at work upon arrival, focusing on west bound Canal and southbound Vista. Lots of gravel and rocks kicked up on sidewalk on Vista.

Corrections issued to Tom with CM and Matt with Lurre.

- continue frequent sweeping until entrane can be correctly installed.
- install geotextilve lining and additional angular rock at entrance.
- install inlet sediment bag @ SW corner of Vista and Canal. NE corner has sediment bag already installed.

Follow up scheduled for Friday. 11/24
Random Inspection11/6/201711/6/201711/6/2017PPASS
DetailsMichael Zawacki
No trackout. Work on foundation of building.
General Inspection10/23/201710/24/201710/26/2017PPASS
DetailsMichael Zawacki
see how Canal street entrance looks...
Canal and Vista free from trackout.
Tracking Control10/20/201710/23/201710/23/2017APART
DetailsAndy J. Long
Trackout observed Friday has been swept out of the drive lanes on Canal but there is still lots of dirt in the median and in the gutter at entrance.

RP Tom, now onsite. Stated he will have it reswept and push brooms in the gutter. Entrance has angular rock but needs to be turned over because it is now compacted.

Will check for follow up Tuesday PM.

BMP Violation10/20/201710/20/201710/20/2017PFAIL
DetailsMichael Zawacki
Went by site at end of day. No cleanup after work, trackout onto canal and vista,
General Inspection10/10/201710/12/201710/12/2017APASS
DetailsMichael Zawacki
check for permit sign, DI bags on vista.
Di bags and permit installed. Using entrance on Vista and exiting onto W Canal. Left note to please clean trackout at end of day.
BMP Violation10/10/201710/10/201710/10/2017PCANC
DetailsMichael Zawacki
No site preparation, permit not displayed. Need to fix DI on vista and make entrance one way
Permit Ready to Issue  9/8/2017  
Issue & PRINT permit COM  9/8/2017 DONE
Routing - Erosion and Sediment5/5/2017 5/5/2017 DONE
DetailsMelissa Jannusch
Plan approved.
Application received  4/12/2017 DONE
Application submitted via PDS Online on Apr 12 2017 4:29PM