Aging Inspection | 12/25/2018 | 12/25/2018 | 12/26/2018 | | CANC |
Michael Zawacki
|
|
|
|
DOC - Permit Finaled | 12/26/2018 | 12/26/2018 | 12/26/2018 | P | PASS |
Michael Zawacki
|
|
|
|
Aging Inspection | 10/24/2018 | 10/24/2018 | 10/24/2018 | | PASS |
Michael Zawacki
|
|
|
No ESC issues. Lots of activity in site.
|
General Inspection | 8/24/2018 | 8/24/2018 | 8/24/2018 | A | PASS |
Michael Zawacki
|
|
|
check backyard & slope behind fence to greenbelt; should have wattle if not landscaped. Wattle installed along rear of lot and on hillside above greenbelt.
|
General Inspection | 6/22/2018 | 6/25/2018 | 6/25/2018 | A | PART |
Andy J. Long
|
|
|
Wattles are now trenched and staked in at proper intervals as requested.
The overlaps have been installed on top of each other rather than side by side, leaving a gap in wattle perimeter.
Notified Mike with Provision landscaping of the change needed.
|
General Inspection | 6/20/2018 | 6/22/2018 | 6/22/2018 | P | PEND |
Andy J. Long
|
|
|
follow up on wattle installation
Mike with Provision Landscaped called to notify that wattles had been re-installed per specifications. Will check up later today or Monday AM.
|
Conference | 6/19/2018 | 6/20/2018 | 6/20/2018 | A | DONE |
Andy J. Long
|
|
|
Meeting with Mike with Proscape Landscaping (208.514.7457) to provide training and BMP flip guide on wattle installation.
Meeting with Mike with ProVision Landscaping (208.514.7457) to provide training and BMP flipguide on wattle installation. 9 AM
required installation specifications: - 8 " wattle - set wattle in 2-3" deep half circle trench along countour/perimeter (within 1 ft of fence line) - stake wattles at ends and at 4-5 intervals in between. Adjoining sections should be overlapped 6" and staked tightly together - backfill trench dirt on upslope side of wattle
Provided BMP booklet and RP manual. Mike will enroll in class as well
Follow up scheduled Friday 6/22 PM
|
General Inspection | 6/14/2018 | 6/15/2018 | 6/18/2018 | A | PART |
Andy J. Long
|
|
|
follow up to check on perimeter wattle installation
Wattle is now installed along back fence as requested.
Wattle installed not per specifications. No trench. No overlap or tight butting.
|
General Inspection | 6/8/2018 | 6/12/2018 | 6/12/2018 | P | FAIL |
Andy J. Long
|
|
|
follow up
No wattles installed as requested. No change in grading or notification of change in landscaping.
Second correction request to Clint. Need to install before the end of the week.
|
General Inspection | 6/8/2018 | 6/8/2018 | 6/8/2018 | P | FAIL |
Andy J. Long
|
|
|
Backfill from foundations pushed to rear of lot. No perimeter control for sediment and earthen berm that was installed to prevent water from going down slope has been graded over.
Correction request to Clint to re-grade berm and install wattle at bottom of subdivision fence.
|
Permit Ready to Issue | | | 10/26/2017 | | DONE |
|
|
|
|
Issue & PRINT permit SFD | | | 10/26/2017 | | DONE |
|
|
|
|
Application received | | | 9/25/2017 | | DONE |
|
|
|
Application submitted via PDS Online on Sep 25 2017 9:53AM
|