Permit Information
Permit NumberESC17-01491
StatusFinaled
Name ZACHARY MEYERS
Site Address 3451 E BARBER VALLEY DR
Project NameWalling Creek Bridge
Customer Number 
ePlanReviewNo
Description
Walling Creek Bridge installation. Project management by Brighton Corp. and City of Boise Parks and Recreation. 404 permits obtained. ESC plan submitted. Contractor is CPC with Syman on BMP installation. Staging area to be at end of Barber Valley Drive and will close east access to MA Williams Park. Pollution prevention BMPs and erosion & sediment controls will be installed on disturbed banks. Project to occur while Walling Creek is not flowing. Dewatering will be required to build bridge foundations, water must be treated before discharge to vegetated area of creek bed. Plan to be submitted after test pits are completed by CPC. Site preparation inspection is required.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
General Inspection1/9/20201/9/20201/9/2020 CANC
DetailsMichael Zawacki
DOC - Permit Finaled1/9/20201/9/20201/9/2020PPASS
DetailsMichael Zawacki
General Inspection12/25/201912/25/201912/26/2019 CANC
DetailsAndy J. Long
General Inspection12/10/201912/10/201912/10/2019 PASS
DetailsMichael Zawacki
Everything around bridge stable.
General Inspection11/25/201911/25/201911/25/2019 PASS
DetailsMichael Zawacki
General Inspection11/8/201911/8/201911/12/2019 PASS
DetailsAndy J. Long
General Inspection10/24/201910/24/201910/25/2019 PASS
DetailsMichael Zawacki
Need to do final walk throug and close permit.
General Inspection10/9/201910/9/201910/9/2019 CANC
DetailsAndy J. Long
General Inspection9/24/20199/24/20199/24/2019 CANC
DetailsAndy J. Long
General Inspection9/9/20199/9/20199/9/2019 PASS
DetailsMichael Zawacki
Revegetated, no issues.
General Inspection8/23/20198/23/20198/23/2019 CANC
DetailsAndy J. Long
General Inspection8/8/20198/8/20198/8/2019 CANC
DetailsAndy J. Long
General Inspection7/24/20197/24/20197/24/2019 PASS
DetailsAndy J. Long
General Inspection7/9/20197/9/20197/9/2019 PASS
DetailsMichael Zawacki
Banks are stable, no esc issues.
General Inspection6/24/20196/24/20196/24/2019 CANC
DetailsAndy J. Long
General Inspection6/7/20196/7/20196/10/2019 CANC
DetailsAndy J. Long
General Inspection5/23/20195/23/20195/23/2019 PASS
DetailsMichael Zawacki
Creek is flowing clean. No rills or runoff going to creek.
General Inspection5/8/20195/8/20195/8/2019 PASS
DetailsMichael Zawacki
Monitor until townhomes completed and area cleaned.
General Inspection4/23/20194/23/20194/23/2019 PASS
DetailsMichael Zawacki
Will have site walkthrough when townhomes next door completed.
General Inspection4/8/20194/8/20194/8/2019 PASS
DetailsMichael Zawacki
Permit will be closed after townhomes completed and satisfactory cleanup of creek and surrounding area. Permit is currently just to monitor site.
General Inspection3/22/20193/22/20193/22/2019 CANC
DetailsAndy J. Long
General Inspection3/7/20193/7/20193/7/2019 PASS
DetailsAndy J. Long
General Inspection2/20/20192/20/20192/26/2019 PASS
DetailsMichael Zawacki
Will do site walk in spring
General Inspection2/1/20192/4/20192/6/2019PPASS
DetailsMichael Zawacki
All BMPs removed. Will continue to monitor until spring.
General Inspection1/29/20191/29/20192/1/2019 CANC
DetailsAndy J. Long
General Inspection1/14/20191/14/20191/14/2019 PEND
DetailsAndy J. Long
General Inspection12/28/201812/28/201812/28/2018 PASS
DetailsMichael Zawacki
Site frozen and stable.
General Inspection12/13/201812/13/201812/13/2018 PASS
DetailsMichael Zawacki
All BMPs removed. Grades down to water are in process of revegetation. No rilling or runoff into creek.
General Inspection11/28/201811/28/201811/29/2018 CANC
DetailsAndy J. Long
General Inspection11/13/201811/13/201811/14/2018 PEND
DetailsAndy J. Long
General Inspection10/26/201810/26/201810/26/2018 PASS
DetailsMichael Zawacki
Banks are growing and mostly stabalized. Landscaping completed.
General Inspection10/11/201810/11/201810/11/2018 PASS
DetailsAndy J. Long
General Inspection9/26/20189/26/20189/26/2018 PASS
DetailsMichael Zawacki
Landscape and sign complete. Still some areas where crews accessed creek that aren't stable.
General Inspection9/11/20189/11/20189/11/2018 PEND
DetailsAndy J. Long
Bridge complete. No ESC corrections directly related to project.

ESC permit to remain open for a coordinated old BMP and construction related trash pick up in Walling Creek between the new bridge and Parkcenter. Partners will be Brighton Corp, Brighton Homes, Boise ESC divisision and BPR.

Date of pickup tbd, October or November.
General Inspection8/24/20188/24/20188/24/2018PPASS
DetailsAndy J. Long
Bridge is complete and open. BMPs removed from creek area directly downstream of bridge. No materials or dirty surfaces left on site.

Banks on either side are vegetating, will monitor through Fall.
Fees Due Hold4/3/2018 8/1/2018 DONE
DetailsTiffany Carson-Herker
sent statment to the GC 4-17-18
General Inspection6/29/20187/13/20187/12/2018APASS
DetailsMichael Zawacki
Silt fence still around creek, other BMPs have been removed. Eagle Landscape is on site doing rock work near bridge. Trench with line running along sidewalk.
Random Inspection6/29/20186/29/20186/29/2018PFAIL
DetailsMichael Zawacki
None of the requested corrections completed. Scheduled follow up for 4-13
General Inspection6/20/20186/20/20186/21/2018PFAIL
DetailsAndy J. Long
Bridge is complete, but not yet open WIP on park monument sign. Shoulders and banks have had a seed and tacifier application. No temp BMPs left in creek, trash around banks is picked up.

Corrections needed:

- remove downed section of SF on NW side of bridge along creek. Install new sediment barrier/buffer below the bank
- remove BMPs installed in basin between Warm Springs bypass and pathway.
- check erosion observed on shoulds of road between bypass and bridge, may need additional stabilization
- pay outstanding special investigation fees to the PDS permit desk
General Inspection4/5/20184/5/20184/5/2018PPART
DetailsAndy J. Long
Follow up inspection. Dewatering was completed last Friday. Temporary holding area has now almost infiltrated. Silt fence across creek has bee removed. No turbid water in Walling Creek from site. Water levels have also been raised in creek.

Corrective actions to complete as project wraps up:
- sweep and clean staging area/parking area at MA Williams park.
- pick up windblown trash up stream from bridge.
- pay special investigation fee applied for last weeks turbid discharge and associated time spent by ESC division to request and obseve corrective actions as well as sampling.



BMP Violation3/30/20183/30/20183/30/2018PPEND
DetailsAndy J. Long
Turbidity samples of Walling Creek at first downstream pedestrian bridge were 190 NTU and 168 NTU. Well above the permissable +50 NTU over background level.

Plume had not reached east Parkcenter Bridge as of 12 PM. River is reading 13.9 NTU at Walling Creek confluence.


Crews moved dewatering hose to the basin between Greenbelt and Warm Springs bypass. Initial location where hose was moved too was found to have and outlet back to creek. This outlet now has additional controls should there be any overflow of first basin area.

2 hour investigation fee charged. Request to complete corrective action report and monitor until dewatering is complete, which is supposed to be today.

Discharge to waterway was stopped with 90 minutes of arriving at site.

Initial inspection, turbidity sampling, and investigation from 9:45-12 PM
Random Inspection3/30/20183/30/20183/30/2018PFAIL
DetailsAndy J. Long
Crews dismantling settling structure while also pumping dirty water into system. Silt fence has lifted up and muddy water flowing down Walling Creek.

Immediate request to extend hose and land apply to the NW between greenbelt and Warm Springs bypass.. Do not want to flood excavation area so cannot shut down pump.

Notified RP and Syman to respond
General Inspection3/20/20183/20/20183/20/2018PPASS
DetailsAndy J. Long
WIP on bridge deck. No trackout to Warm Springs bypass or BV Drive. Staging area is clean, no spills , loose trash, or mud. Dewatering water is clear passing out of settling chamber.

RP stated that within in the next few weeks disturbed areas within creek area will be seeded with an approved wetland plant & seed mix (per Parks and Rec)
Random Inspection3/12/20183/12/20183/12/2018PPASS
DetailsMichael Zawacki
WIP on bridge deck. Well point in place and pumping water from below excavated level, water is crystal clear and free from foam and odors. Diesel for generator has been placed in tote as a secondary containment. No issues with dirt leaving on Barber Valley or Warm Springs. Washout on north side of project, installed correctly and maintained.
General Inspection1/19/20181/19/20181/22/2018PPASS
DetailsAndy J. Long
Inspection on Friday 1/19. No activity at site. No trackout or issues in staging area at MA Williams park. Concrete washout is lined and on north side of creek. Dewateriing on-going, water is not visibly turbid and is going through settling system and silt fence.

No corrections requested.
Random Inspection1/5/20181/5/20181/5/2018PPASS
DetailsAndy J. Long
WIP on bridge pylon footings. No trackout or discharge from staging area. No spills observed. Dewatering operation is running, water going into settling basin is clear. No plumes observed downstream. Approved.
General Inspection1/2/20181/2/20181/2/2018PPASS
DetailsMichael Zawacki
WIP on footings. Washout on site between green belt and warm springs ave. Water leaving site is cleaner than groundwater reaching surface. Excavating and hauling away fill dirt, no trackout issues.
Random Inspection12/21/201712/21/201712/21/2017PPASS
DetailsMichael Zawacki
Working on installation of footings. Dewatering still in process. Spring turbity is 1.92 NTU, after pumping and treatment return water is 12.9 NTU
General Inspection11/20/201711/20/201711/20/2017APASS
DetailsMichael Zawacki
dewatering check up.
No work today. Pumps are turned off and hole is flooded.
General Inspection11/15/201711/15/201711/15/2017PPASS
DetailsMichael Zawacki
Getting second pump set.
General Inspection11/13/201711/13/201711/13/2017APASS
DetailsMichael Zawacki
Dewatering in process. Coming out and pooling behind silt fence. Water is absorbing into ground into marsh. Didn't see any running surface water further down stream. Zane said they will sweep trackout up.
General Inspection11/9/201711/9/201711/9/2017APEND
DetailsMichael Zawacki
check on dewatering
Containment built. Wells not dug and no pumps yet in place.
Site Preparation11/8/201711/8/201711/8/2017PPEND
DetailsAndy J. Long
check on dewatering plan setup
dewatering not yet commenced. Materials for settling chamber are now on site. Syman Co. installing perimeter controls.

Note:

Need to have BPR and Brighton remove old silt fence along Walling Creek downstream from bridge site.

Will check back later today or tomorrow AM to confirm water treatment. There is some backed up water in Creek about 100 M downstream
Site Preparation11/6/201711/6/201711/6/2017PPEND
DetailsMichael Zawacki
Road closure set. No BMPs or staging.
PLANS/APPL TAKEN TO FRONT DESK  11/3/2017 DONE
Permit Ready to Issue  11/3/2017 DONE
All Met
Telephone call  11/3/2017 DONE
Called Zach to let him know permit is ready and what fees are due.
Issue & PRINT permit COM  11/3/2017 DONE
Application received  10/31/2017  
Routing - Erosion and Sediment10/31/2017 10/31/2017 PASS
DetailsAndy J. Long
ESC plan approved. Valid RP. Site preparation inspection required. Dewatering plan to be submitted and implented prior to discharge.