Permit Information
Permit NumberESC18-01444
StatusFinaled
Name TIM NIEHOFF
Site Address 11389 W GABRIELLE DR
Project NameGALAHAD SUBDIVISION PHASE 1
Customer Number 
ePlanReviewNo
Description
This project will consist of 4 townhouse buildings, landscaping, parking, and underground utilities. The site is approximately 1.6 acres.
Contact Information
See Activities list for contact information
Show Inspection Activities Only
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
General Inspection3/6/20203/6/20203/6/2020 CANC
DetailsMichael Zawacki
DOC - Permit Finaled3/6/20203/6/20203/6/2020PPASS
DetailsMichael Zawacki
All units done and landscaped. Will monitor site under phase 2 permit ESC19-00160
General Inspection1/30/20202/4/20202/4/2020PPEND
DetailsAndy J. Long
No trackout. No new activity on west phase. Site still needs a construction entrance installed, currently muddy entrance is blocked. Still quite a bit of trash on the north side of Gabrielle from site. Will follow up with Sterling homes
General Inspection1/30/20201/30/20201/30/2020 CANC
DetailsAndy J. Long
rescheduled
General Inspection12/30/201912/30/201912/30/2019 PASS
DetailsMichael Zawacki
No work has begun on new phase. Trash is in giant pile in back of site. No trackout or issues.
General Inspection11/27/201911/27/201911/27/2019PPASS
DetailsMichael Zawacki
Follow up looking for blowing trash.
No issues.
General Inspection11/26/201911/26/201911/26/2019 PEND
DetailsMichael Zawacki
Landscape crew on site cleaning lots and getting them prepped. West lot has lots of trash piles. Cleanup crew says they're getting t taken care off.
General Inspection10/25/201910/25/201910/25/2019 CANC
DetailsMichael Zawacki
General Inspection9/24/20199/24/20199/24/2019 PASS
DetailsMichael Zawacki
hase 1 on east has all buildings framed. Parking lot is scheduled to be paved in a few weeks. Joint trench has just begun on phase 2 to the west. Weeds have grown near wattle acting as natural buffer. No current concrete walk, trash is being cleaned.
No blowing dust or trackout.
BMP Violation8/7/20198/14/20198/13/2019APASS
DetailsMichael Zawacki
Inspected 8-12.
Area has been cleaned, still some dirt on aprons.
General Inspection8/7/20198/7/20198/7/2019 FAIL
DetailsMichael Zawacki
Multiple piles of uncontained washout, building debris laying around, streets need to be cleaned.
Corrective action request will be sent to RP, follow up scheduled.
General Inspection6/10/20196/10/20196/10/2019PPASS
DetailsMichael Zawacki
Foundations LLC on site getting prepped. Grader is on site prepping road bed, pipe crew doing some trench work. Street is clean, DI bags in good shape. No dust at time of inspection.
General Inspection5/22/20195/22/20195/22/2019PPASS
DetailsMichael Zawacki
Curtis came yesterday and swept. Construction entrance, having trucks unload without need to drive onto lot. Continuing to sweep sidewalks and gutters.
General Inspection5/2/20195/9/20195/10/2019APART
DetailsMichael Zawacki
Water truck on site causing some track out. Crew stopped work and cleaned up.
General Inspection5/2/20195/2/20195/2/2019PPEND
DetailsMichael Zawacki
Spoke with Tim the RP while on site. Has Curtis scheduled to sweep this afternoon. Will check DIs and clean aprons. Will be moving to East entrance starting on Monday. Will check site next week.
Site Preparation4/3/20194/5/20194/8/2019APART
DetailsMichael Zawacki
Construction entrance is road mix, not stabalized. Road bed streets are starting to be laid out on site. West end has some runoff into gutter, no stabalized entrance by storage yard. West end wattle is end to end, not overlapping.
BMP Violation3/28/20194/3/20194/3/2019PPEND
DetailsMichael Zawacki
Crew on site installing BMPs. Follow up scheduled for Friday.
General Inspection3/28/20193/28/20193/28/2019PFAIL
DetailsMichael Zawacki
1. No permit or SWPPP info posted
2. Track out onto aprons
3. Mud deposited in gutters
4. Drain inlet protection not maintained, full of debris, dirt, and trash
5. Materials strewn about, no staging area or trash container
6. No useable construction entrance, no entrance being used.
7. No perimeter BMPs
Correction notice sent to listed RP
Site Preparation2/8/20192/12/20192/12/2019PFAIL
DetailsAndy J. Long
1 PM Tim RP

*note - project already started. Reviewed site prep requirement with RP. RP states BMPs are installed.

Corrections needed:

- install construction entrance.
- sweep dirt and mud in aprons and gutter
- pick up loose trash and provide trash container
- post ESC permit sign and SWPPP information.
General Inspection2/5/20192/6/20192/8/2019ACANC
DetailsAndy J. Long
rescheduled for site preparation inspection.
Issue & PRINT permit SFD  1/10/2019 DONE
Routing - Erosion and Sediment10/11/2018 10/11/2018 DONE
DetailsMichael Zawacki
RP needed before construction activity. Site prep inspection required.
Application received  10/3/2018 DONE
Application submitted via PDS Online on Oct 3 2018 8:13AM