DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
DOC - Permit Finaled5/4/20205/4/20205/4/2020PPASS
DetailsMichael Zawacki
General Inspection5/1/20205/4/20205/4/2020PPASS
DetailsMichael Zawacki
final out finishe units
General Inspection5/1/20205/1/20205/1/2020 CANC
DetailsAndy J. Long
General Inspection3/16/20203/16/20203/16/2020 PASS
DetailsMichael Zawacki
Site is clean and contained. Genie lift running in back by railroad, if it comes out area gets cleaned. No blowing trash or trackout. Will get a washout for paint, drywall, and stucco on next phase.
General Inspection1/29/20201/29/20201/31/2020PPASS
DetailsAndy J. Long
NO trackout. BMPs installed. Construction entrance being used. Added additional rock between building and train tracks to keep down mud and make room for parking & deliveries out of the mud.

Was notified that they dewatered a large puddle into grass across the tracks. Perimter is clean. NO corrections requested.
Random Inspection1/6/20201/6/20201/6/2020PPASS
DetailsAndy J. Long
New construction entrance installed at east end of site for loading and access to back area. No trackout observed
General Inspection12/18/201912/23/201912/24/2019PPASS
DetailsMichael Zawacki
North gate closed, still waiting for rock deliverie.
Drywallers will bring their own washout container, said they will stop dumping.
Will bring in washout pan for next concrete work, have excavator clean old washout.
No current stucco work.
Tracking Control12/13/201912/16/201912/18/2019PPART
DetailsAndy J. Long
Gate to muddy parking area has been closed. Site is requiring workers to park offsite on Columbus or Vista Village. Storm drain protection installed on Kootenai. No significant trackout.

Request to sweep paved entrance area, lots of loose dirt/dried mud.

Request to provide a washout container for dry wall equipment rinsing and paint and to build a bermed area around the stucco machine.
Conference12/13/201912/13/201912/13/2019PDONE
DetailsAndy J. Long
Meeting and verbal correction request to project manager David:

- install construction entrance per details. Angular rock. 50 ft or greater in length
- need to install sediment protection on receiving storm drain west of site on Kootenai
- install gravel check bags in gutter, down gradient from entrance.
- install gravel chip in employee parking area or find alternative parking area.
- needs to RP class

Follow up next week scheduled
Tracking Control12/13/201912/13/201912/13/2019PFAIL
DetailsAndy J. Long
Inadequate construction entrance on the east access.

Request to close gate and/or stabiilze the entrance and route through puddle.

RP listed is project manager and needs to be updated.

Follow up scheduled
General Inspection11/8/201911/8/201911/13/2019PPASS
DetailsMichael Zawacki
All foundations poured and parking lot paved. Work is all framing or interior, site is clean, no issues.
General Inspection9/20/20199/20/20199/20/2019PPASS
DetailsMichael Zawacki
Met with foreman and project manager at site.
Crew on site and is getting ready to pave inside site. Workers currently parked in low spot, will use pavement when completed. Apron leaving site has been paved, rock entrance on site.
Central Paving is doing ACHD job and hauling through site.
PM may attend RP class in October.
BMP Violation8/26/20198/26/20198/26/2019PPASS
DetailsMichael Zawacki
follow up on concrete washout pit
BMP Violation8/14/20198/21/20198/20/2019APART
DetailsMichael Zawacki
Construction entrance extended and workers now parking closer to railroad tracks where it is rock,
Washout is now lined.
One front end loader running around kicking up lots of dust, some dust trackout, stained but no chunks of dirt.
Tracking Control8/9/20198/12/20198/14/2019AFAIL
DetailsMichael Zawacki
Road is clean, needs new construction entrance and to be extended due to dust.
Washout pit has been dug but is not lined.
Pictures sent to RP.
Follow up scheduled.
General Inspection7/2/20197/2/20197/2/2019PPASS
DetailsAndy J. Long
No activity at time of inspection. Kootenai Road project is still in progress and very dusty.

Sewer and utilities in process of being installed. No corrections requested.
General Inspection5/3/20195/9/20195/10/2019PPASS
DetailsAndy J. Long
Site Preparation5/2/20195/2/20195/3/2019PPASS
DetailsAndy J. Long
Andrew Phone #: ###-####

Site adjacent to active Kootenai St widening project. Perimeter established by raised train tracks.

Approved to start initial ground work.
Permit Ready to Issue  5/2/2019 DONE
Issue & PRINT permit COM  5/2/2019 DONE
Routing - Erosion and Sediment3/4/2019 3/4/2019 DONE
DetailsMichael Zawacki
Site prep inspection required.
Application received  2/12/2019 DONE
Application submitted via PDS Online on Feb 12 2019 12:25PM