General Inspection | 7/31/2020 | 7/31/2020 | 8/3/2020 | | PASS |
Michael Zawacki
|
|
|
No new activity.
|
General Inspection | 7/16/2020 | 7/16/2020 | 7/16/2020 | | PASS |
Michael Zawacki
|
|
|
East side is grown and stable. No new activity on west side. Some areas will need reapplication of seed in fall. No building.
|
General Inspection | 7/1/2020 | 7/1/2020 | 7/7/2020 | | CANC |
Andy J. Long
|
|
|
|
General Inspection | 6/16/2020 | 6/16/2020 | 6/16/2020 | P | PART |
Michael Zawacki
|
|
|
All lots were repaired after last rain event. Some rills and sediment within site. Rill formed on old trench for water, blew through first row of wattle. Was all caught by vegetation and second row of wattle. East side is stable. East side has water running of BB road and rilling, causing blowout of trail on other side of road from water directed into culvert.
|
General Inspection | 6/8/2020 | 6/8/2020 | 6/8/2020 | P | PART |
Michael Zawacki
|
|
|
Met with Scott at site. Some rilling coming down middle where sewer was ran. Already on site with skid steer to make repairs. Walking path was blown out from water coming through culvert.
|
General Inspection | 6/4/2020 | 6/4/2020 | 6/4/2020 | | PASS |
Michael Zawacki
|
|
|
Trench work done and equipment off site. A few of the upper lots re graded. No repairs made to disturbed areas. Few sections of sidewalk need to be repoured. Road needs some patchwork.
|
Conference | 5/19/2020 | 5/20/2020 | 5/20/2020 | A | DONE |
Andy J. Long
|
|
|
notify ACHD about the roadway runoff issue
|
General Inspection | 5/19/2020 | 5/19/2020 | 5/19/2020 | P | PEND |
Andy J. Long
|
|
|
Runoff from Bogus Basin Road causing erosion on road shoulder. ACHD installed the existing rip rap, not the construction site.
GC/RP Scott said that tomorrow outfall on the culvert on west side of road near trail will get repaired.
Going to notify ACHD of the roadway runoff issue
|
General Inspection | 5/14/2020 | 5/14/2020 | 5/14/2020 | | PART |
Michael Zawacki
|
|
|
Hillside trenches filled, heavy equipment moved. No tracking on exposed hillsides. Hills need to be reseeded. ots of dirt tracked onto road within site and left.
|
General Inspection | 4/28/2020 | 4/28/2020 | 4/30/2020 | | PEND |
Andy J. Long
|
|
|
see also ESC19-00994 for Hackberry Ridge inspections
WIP on utilities. Much of the hydroseeded area has been disturbed. Trenches up the slopes to the lots on the ridge.
The berms on the lots and the erosion controls damaged will need to be replaced.
|
General Inspection | 4/9/2020 | 4/9/2020 | 4/9/2020 | | PART |
Michael Zawacki
|
|
|
Some random small windblown trash on hillside, cans, wrappers, etc. Some runoff onto sidewalks, all ends up in site system.
|
General Inspection | 3/25/2020 | 3/25/2020 | 3/25/2020 | | PASS |
Michael Zawacki
|
|
|
No issues on east side of BB Rd., grass starting to sprout. Joint trench work has begun on west side. Tracks up the hillside, some BMPs destroyed. Will need to monitor and repair as needed.
|
General Inspection | 3/10/2020 | 3/10/2020 | 3/12/2020 | | PASS |
Michael Zawacki
|
|
|
One section on east along BB road is rilling onto lower area of property. All the other lots are stable and in good condition.
|
General Inspection | 2/6/2020 | 2/6/2020 | 2/6/2020 | P | PEND |
Michael Zawacki
|
|
|
No issues on west side. East side has large rill forming near road and going to low spot of site. RP has already been notified.
|
General Inspection | 1/27/2020 | 1/27/2020 | 1/27/2020 | P | PASS |
Michael Zawacki
|
|
|
Everything at phase is good. No blowouts from lots or rilling.
|
General Inspection | 1/24/2020 | 1/24/2020 | 1/24/2020 | P | PASS |
Michael Zawacki
|
|
|
Hillsides hydroseeded and BMPs installed as needed. Lots have been bermed. No issues at site.
|
General Inspection | 12/23/2019 | 12/23/2019 | 12/23/2019 | P | PASS |
Michael Zawacki
|
|
|
All hillsides and lots on both sides of road in good shape. No erosion issues. Some game trails across tackified hillsides.
|
General Inspection | 11/25/2019 | 11/25/2019 | 11/25/2019 | P | PASS |
Michael Zawacki
|
|
|
Both sides of Bogus Basin road hydroseeded and have wattle installed.
|
Issue & PRINT permit SFD | | | 11/20/2019 | | DONE |
|
|
|
|
Routing - Erosion and Sediment | 6/24/2019 | | 6/24/2019 | | DONE |
Andy J. Long
|
|
|
SWPPP and ESC site plan approved. Certified stormwater team designated. Site preparation inspection, preconstruction conference required.
|
Application received | | | 5/28/2019 | | DONE |
|
|
|
Application submitted via PDS Online on May 28 2019 8:30AM
|